© 2020 - perma-tec
GmbH & Co. KG
|
www.perma-tec.com
|
17
16
|
perma ECOSY
CAUTION
5
Mounting
5.1
Electrical Requirements
•
Power supply with 24 V DC, 25 W
8-pole plug (see chapter 10.2) included
Cable cross-section at least 0.75 mm
2
(0.03 in
2
)
•
Power supply with 85 - 240 V AC / 50 - 60 Hz
4-pole plug (see chapter 10.1) included
Cable cross-section at least 0.75 mm
2
(0.03 in
2
)
Do not use wire-end sleeves!
5.2
Required Tools (depending on mounting location )
• Tape measure
• Water level
• Flat wrench
• Allen wrench
5.3
Mounting the Lubrication System
Mounting material is not included!
Mounting material depends on the conditions on site and is not
provided by perma-tec.
5.3.1 Mounting of Lubrication System and Tubes
We recommend that you fix the lubrication system with bolts M8 and
DIN EN ISO 7090 washers or that you use a similar fixing method.
Existing equipment can be used.
• Pay attention to the required clearance for the filling container
and the filling device (Fig. 3-3).
• Bore the holes horizontally at a distance of 190 ± 5 mm (7.48 ± 0.2 in)
according to fig. 3-3 and fix the system with screws. Finger tighten
screws and add a quarter turn.
• Remove cover of pump compartment (4, Fig. 3-1).
• Connect perma ECOSY 5 outlets with the lubrication point using tube
or hose connections. Outlet number is imprinted on the distributor
housing.
• Inactive outlets should be tightly sealed with a plug or blind plug.
• Connect tube lines tightly and securely with grease points (spray
valve, brushes etc.).