© 2020 - perma-tec
GmbH & Co. KG
|
www.perma-tec.com
|
35
34
|
perma ECOSY
8.4.1.4 Additional Discharge
Additional discharges can be triggered by applying a control signal
to input “Impulse IN” (Plug B, PIN 5).
These discharges are carried out independently of the selected
operating mode.
When triggering an “additional discharge”, all outlets are supplied
with the same amount of lubricant.
The additional discharge can only be carried out when the lubrica-
tion system is turned on (display “ON”).
8.4.2 Setting of Operating Mode
ECOSY
System On
+20 °C
Menu
B1
Press “Menu”.
B18
Menu
Parameter
Configuration
OK << >> Esc
B18
Select “Configuration” by pressing
the arrows “>>”.
B19
Menu
Configuration
Test run
OK << >> Esc
B19
Press “OK”.
B20
Configuration
Operating mode
Temp. unit
OK << >> Esc
B20
“Operating mode” is already selected.
Press “OK” (after selected PIN was
confirmed according to chapter 8.4.6).
B21