perma ECOSY
# Error
Possible causes
Suggestet solution
3
ECOSY 5 displays:
“Error outlet X
blocked”
Outlet X blocked.
If less than six outlets are
used, the wrong outlet could
be sealed or connected.
- Check tube and lubrica-
tion point for bends and
blockages.
- Check menu for activated
outlets and check which
outlets were mechanically
sealed with a plug (mech.
sealed outlets can not be
activated).
4
ECOSY 5 displays:
“Error pump not
working”
Stroke recognition of pump
defective or defective pump.
- Send perma ECOSY 5 to
your local supplier for
repairs.
5
ECOSY 5 displays:
“Error internal
communication“
I
2
C communication on the
electronic unit causes error.
- Send perma ECOSY 5 to
your local supplier for
repairs.
6
ECOSY 5 displays:
“Error No. X disch.
overflow
”
There are more than 5 dis-
charges for a single
outlet lined up.
More than 5 test runs have
been entered or the outlet
is blocked and has been
switched off.
- Acknowledge the error.
Check if the outlet is
blocked.
- Do not enter more than
5 test runs in a row.
7
ECOSY 5 displays:
“Error distrib.
drive”
The current was permanent-
ly too high / too low during
operation.
Distributor with mechanical
defect.
Distributor not connected.
- Counter-pressure of the
system is too high. Check
if outlets are blocked.
- Send perma ECOSY 5 to
your local supplier for
repairs.
8
ECOSY 5 diplays:
“Error distrib.
position”
Distribution position sensor
not found.
- Send perma ECOSY 5 to
your local supplier for
repairs.
9
ECOSY 5 displays
“Error distrib.
initialization”
Distributor initialization
sensor not found.
Number of outlets does not
correspond to the initializa-
tion value.
- Send perma ECOSY 5 to
your local supplier for
repairs.
- Disconnect perma ECOSY 5
from power supply and
reconnect it after 30 sec.
perma ECOSY 5 carries out
initialization. If the same
error occurs again, send
the ECOSY 5 to your local
supplier for repairs.