CT/L-04.2 Controller
5.6.3 Outputs
LdA
,
LdSt
,
LdB
The controller is equipped with three outputs type “TTL”:
LdA
,
LdSt
,
LdB
. Connection should
be performed to the contacts of
XT2
connecting block of the controller bottom board.
Outputs can be used (Figure 3):
as outputs of connection of indication of the RC-panel,
as outputs of control of other optional equipment (OUT #7, OUT #8, OUT #9).
Characteristics of output signals:
Maximum voltage of direct current ................................................................. max. 3 V
Maximum current....................................................................................... max. 0.01 A
5.7 Parameters of signals received on inputs «
Ш
C1»
and «
Ш
C2»
The controller provides the status control of two inputs
Ш
C1
and
Ш
C2
. Connection to the
inputs is carried out via the connecting block
XT10
of controller bottom board.
Every input can be used as input of alarm line or as standard input to connect the lock
RC-button or to connect optional equipment (IN #5, IN #6), see Figure 3. The input
selection depends on the selected controller configuration and the position of the jumper
on the connector
XP9
or
XP10
on the controller bottom board. Installation of the jumper in
the position 2-3 corresponds to the configuration “standard input”.
Attention!
When you select the controller configuration with one or two ALs (see Sect. 5.4),
you need to put jumpers on the controller bottom board in the position 1-2 (see
Figure 1):
on the connecting block
XP10
with configuration “1 AL”,
on the connecting blocks
XP9
and
XP10
with configuration “2 ALs”.
5.7.1 “Standard” input configuration
Jumper
XP9
(for
Ш
C1
) or
XP10
(for
Ш
C2
) is in the position 2-3. The controller provides the
control input status
Ш
C1- ÷ GND
(
Ш
C2- ÷ GND)
under control output type “dry contact” or
“open collector” (O
К
).
Note:
To create a high-level signal on inputs contacts
Ш
C1-
and
Ш
C2-
relative to
GND
,
the resistors with 1kOhm resistance are used. They are connected to +5 V power
line. The resistors with 392 Ohm are connected to the minus of power supply.
In this configuration input can be used:
Ш
C1- ÷ GND
:
o
as input for connection of RC-button for the lock (RC OD #3);
o
as input for connection of optional equipment (IN #5
).
Ш
C2- ÷ GND
:
o
as input for connection of RC-button for the lock (RC OD #4);
o
as input for connection of optional equipment (IN #6
).
Activation of all signals depends on description of their initial status in
Normal status of
contact
parameter in
PERCo-Web
software:
If input is described as
Opened
, it is activated by a turn-on of low-level signal relative
to
GND
contact. In such case a normally open relay contact or a scheme of open
collector output may be a control element.
If input is described as
Closed,
it is activated by a turn-off of low-level signal relative to
GND
contact. In such case a normally closed relay contact or a circuit of open
collector output may be a control element.
15
Summary of Contents for CT/L-04.2
Page 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...
Page 2: ...Controller CT L 04 2 Assembly Operation Manual...
Page 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...
Page 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...
Page 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...
Page 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...
Page 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...
Page 70: ...www perco com...