Assembly & Operation Manual
Procedure of controller connection
Cables used in installation are mentioned in Table 6. When you connect the controller
through the splitter, follow the next procedure:
1. Find the mounting place of the splitter. It is recommended to install the splitter inside
of controller housing (do not install the splitter from the controller at distance more
than 2m).
2. Connect
Ethernet
cable from the controller to
Con2
connector of the splitter.
3. Connect the power supply to
Con3
connector. If necessary OD can be connected to
Con3
connector too. Connection scheme is shown on Figure 19 (plug for connection
to connector is on delivery kit of the splitter).
4. Connect
Ethernet
cable from
Switch
to
Con1
connector of the splitter.
5. Connected device will be powered after verification between
Switch
and the splitter.
In case if you need to power off the controller, it is sufficient to disconnect
Ethernet
cable
(from
Switch
) from
Con1
connector of the splitter.
Figure 19. Connection scheme of the controller through
PoE
-splitter
48
Summary of Contents for CT/L-04.2
Page 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...
Page 2: ...Controller CT L 04 2 Assembly Operation Manual...
Page 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...
Page 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...
Page 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...
Page 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...
Page 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...
Page 70: ...www perco com...