Assembly & Operation Manual
5. Emergency devices
Fire Alarm
are connected to
XT2
connecting block of bottom
board of the controller (in this case it is necessary to remove jumper by cord), Figure 5
and Sect. 8.2.6.
6. Fix cables with plastic ties to self-adhesive cable tie mount, included into delivery set,
by installing them inside of the controller the housing.
Figure 5. Connection scheme for RC-button and door sensors
8.2.3 Turnstile and electromechanical gates configuration
Notes:
The
Device output mode of operation
parameter of OD should be in
Potential
for
PERCo
turnstiles.
The
Registration of the passage after ID card presentation
parameter of OD
should be in
Yes
for swing gate
WMD-05S
and
WMD-06
.
Follow the next recommendations to connect the turnstile (the gate) to controller:
1. To dissipate static electricity, is recommended to ground the housing of turnstile. It is
necessary to use the cable with cross section minimum 0.75 mm.
2. Connect the turnstile (the control unit of the turnstile) to
XT1
,
XT6
,
XT7
connecting
blocks of the controller bottom plate in compliance with the scheme (Figure 6).
3. Connect the swing gate (the control unit of the turnstile) to
XT1
,
XT6
,
and
XT7
connecting blocks of the bottom board of the controller in compliance with the scheme
(Figure 7).
Note:
Connection scheme of power circuit of the controller and the turnstile (the gate) in
case of connection via
PoE
-splitter is given on Figure 19.
4. Connect RC-panel (or WRC) to
XT2
connecting block of the lower board of the
controller in compliance with the scheme (Figure 10).
5. Fix cables with plastic ties to self-adhesive cable tie mount, included into delivery set,
by installing them inside the housing of the controller.
24
Summary of Contents for CT/L-04.2
Page 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...
Page 2: ...Controller CT L 04 2 Assembly Operation Manual...
Page 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...
Page 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...
Page 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...
Page 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...
Page 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...
Page 70: ...www perco com...