CT/L-04.2 Controller
3 TECHNICAL SPECIFICATIONS
Operating voltage ................................................................................................... 12±1.2V
Consumption current (12V) .................................................................................. max. 0.2A
Power consumption ............................................................................................ max. 2.5W
Communication interface standard ...................................................
Ethernet
(IEEE 802.3)
Ethernet
data transfer speed
..........................................................................
10/100
Mbps
Number of controlled ODs ...................................................................................... up to 4
1
Number of reading devices ....................................................................................... up to 8
Interface of reading devices ..................................................................................... RS-485
Number of access cards (users) ..................................... from 10,000 to 50,000 (see Note)
Event memory capacity
2
............................................. from 230,000 to 870,000 (see Note)
Note:
The user is able to change the memory allocation of the controller via the
Web-interface. Other options of memory allocation (see Appendix 5, Clause 3.4):
- 50 000 cards and 230 000 events (by default).
- 40 000 cards and 390 000 events.
- 30 000 cards and 550 000 events.
- 20 000 cards and 710 000 events.
- 10 000 cards and 870 000 events
Number of relay outputs for OD control ............................................................................. 4
Number of additional “open collector” outputs ................................................................... 2
Number of inputs with line control for short circuit and line break
(controlled by “dry contact” outputs) ................................................................. up to 8
Number of alarm lines ............................................................................................... up to 2
Number of remote control inputs ............................................................................... up to 4
Number of remote control indication outputs ..................................................................... 4
Electric shock protection class ...................................................................... III (IEC 61140)
Mean lifetime ........................................................................................................... 8
years
Dimensions ............................................................................................... 205×189×45 mm
Weight
............................................................................................................... max. 1.8 kg
1
Depends on the selected controller configuration (see Section 5.4).
2
Events from connected
CL-201
controllers are stored in the memory of
CT/L-04.2
controller.
5
Summary of Contents for CT/L-04.2
Page 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...
Page 2: ...Controller CT L 04 2 Assembly Operation Manual...
Page 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...
Page 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...
Page 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...
Page 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...
Page 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...
Page 70: ...www perco com...