CT/L-04.2 Controller
Figure 4. Connection schemes of the locks
2. Connect the lock (the latch) to
XT6
or
XT9
connecting blocks on the lower board of the
controller is made in accordance with scheme (Figures 3 - 5).
3. If you need to connect remote control button, connect it to
XT2
(
XT10
) of lower board
of the controller (Figure 5).
4. The reed switch is connected to
XT1
connecting bloc of lower board (Figure 5). The
door sensor with the lock controlled by
OUT1
is connected to
IN1
input,
OUT2
to
IN2
,
etc. The door sensor must be mounted that when the door is closed, the sensor can
always actuate.
Note:
The locks
LB-
,
LBP-
series do not require mounting of the door sensor (the
CT/L-04.2
controllers can trace the door opening based on the contact group of the
lock). In this case, is necessary to installed jumpers on the lower board of the
controller: for
OUT1
–
XP5.1
and
XP5.2
, for
OUT2
–
XP6.1
and
XP6.2
, for
OUT3
–
XP7.1
and
XP7.2
, for
OUT4
–
XP8.1
and
XP8.2
(Figure 1).
23
Summary of Contents for CT/L-04.2
Page 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...
Page 2: ...Controller CT L 04 2 Assembly Operation Manual...
Page 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...
Page 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...
Page 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...
Page 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...
Page 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...
Page 70: ...www perco com...