CT/L-04.2 Controller
Signals activation depends on description of their default status in
Normal status of
contact
parameter in
PERCo-Web
software):
If input is described as
Opened
, it is activated by a turn-on
of low-level signal
relative to
GND
contact. In such case a normally opened relay contact or a scheme
of open collector output may be a control element.
If input is described as
Closed
, it is activated by a turn-off of low-level signal relative
to
GND
contact. In such case a normally closed relay contact or a circuit of open
collector output may be a control element.
Note:
Input
IN1
is configured as “Closed” by default.
If according to the configuration of the controller input
IN2, IN3
or
IN4
is used to
connect the door sensor / passage sensor / PASS, that by default is configured
as
Closed
with the possibility of further changes.
Control element “relay contact” should provide following characteristics of signals:
Minimum commutating current ........................................................................ max. 1 mA
Closed contact resistance
(with resistance of the connection cable)................................................ max. 300 Ohm
Control element of circuit with open drain output should provide following characteristics of
signals:
Voltage at the closed contact
(low-level signal at input of the controller)...................................................... max. 0.8 V
5.5.2 Inputs
DUA
,
DUSt
,
DUB
,
FA
The controller provides status control of four inputs under control of “dry contact” or “open
collector” (
OK
):
DUA, DUSt, DUB, FA
. Connection to the inputs is performed via
XT2
connecting block of the controller bottom board.
Note:
To create a high-level signal on all input contacts
DUA, DUSt, DUB, FA,
resistors
with 1 kOhm resistance, connected to +3,3V power line, are used.
Inputs can be used for following connections:
DUA, DUSt, DUB:
o
RC-buttons,
o
RC-panel
(WRC),
DUSt, DUB:
o
optional equipment (IN #7, IN #8);
FA:
o
emergency unlock devices (passage opening)
Fire Alarm.
Activation and characteristics of signals of the control element are specified in the
Sect. 5.5.1.
Note:
Input
FA
is uniquely configured as “Closed”.
Input
DUA
is uniquely configured as “Opened”.
If according to the configuration of the controller input
DUSt
or
DUB
used to
connect RC-buttons, it is uniquely configured as Opened without any possibility
being modified.
13
Summary of Contents for CT/L-04.2
Page 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...
Page 2: ...Controller CT L 04 2 Assembly Operation Manual...
Page 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...
Page 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...
Page 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...
Page 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...
Page 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...
Page 70: ...www perco com...