CT/L-04.2 Controller
Appendix 3. Instruction on connection of the controller
through
PoE
-splitter
Attention!
Instruction provided refers to the splitters included in supplementary equipment
delivery set.
Total power consumption of the controller and of all the devices powered by it
should not exceed 12 W. It is also recommended to leave min 10% reserve
power.
Splitter description
PoE-splitter
(hereinafter –
splitter
) is designed for energizing equipment, connected via
Ethernet
network. Splitter operates with any network commutators (hereinafter –
Switch)
,
supporting technology of electric power transmission via
PoE
twisted pair wire and
compatible with
IEEE 802.3af
standard.
Splitter is designed as a block of electronics in a plastic housing featuring the following
outputs:
Con 1
– output for
Ethernet
cable from
Switch
connection
;
Con 2
– output for
Ethernet
controller cable connection;
Con 3
– power output for controller power cable connection.
Note:
For some models of splitters output voltage is chosen with the switcher. Operating
with
PERCo
equipment it is necessary to turn the switcher into
“12V”
mode.
Requirements for connecting devices
The characteristics of power consumption of the controller when connected through splitter
should meet the following requirements:
Admissible value of supply voltage .............................................................. 12±1.2 V
Minimum total current ............................................................................ min. 120 mA
Maximum total current consumption (12V) ................................................... max 1 A
Maximum total power consumption ........................................................... max 12 W
In order to avoid exceeding the total power consumption is not recommended to provide
power from the controller to connected optional equipment (siren, passage sensors, etc.)
and controllers of the second level. The controller powered from the splitter can be
connected up to four readers and OD (Table 10).
Table 10. OD with power connection through
PoE
-splitter
Types of controller configurations
OD
“Controller to operative to control the
locks”
Electromechanical lock (
LC, LB
and
LBP
-series – up to 4pcs).
“Controller to operate the turnstile”
Turnstile with power consumption
no more than 9W
T-5
TTR-04.1
TTD-03.1
TTD-03.2
47
Summary of Contents for CT/L-04.2
Page 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...
Page 2: ...Controller CT L 04 2 Assembly Operation Manual...
Page 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...
Page 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...
Page 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...
Page 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...
Page 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...
Page 70: ...www perco com...