CT/L-04.2 Controller  

Appendix 3. Instruction on connection of the controller 

through 

PoE

-splitter 

 

Attention! 

  Instruction provided refers to the splitters included in supplementary equipment 

delivery set. 

  Total power consumption of the controller and of all the devices powered by it 

should not exceed 12 W. It is also recommended to leave min 10% reserve 
power. 

Splitter description 

PoE-splitter 

(hereinafter – 

splitter

) is designed for energizing equipment, connected via 

Ethernet

 network. Splitter operates with any network commutators (hereinafter – 

Switch)

supporting technology of electric power transmission via 

PoE

 twisted pair wire and 

compatible with 

IEEE 802.3af

 standard.  

Splitter is designed as a block of electronics in a plastic housing featuring the following 
outputs: 

Con 1

 – output for 

Ethernet

 cable from 

Switch 

connection

;

 

Con 2

 – output for 

Ethernet

 controller cable connection; 

Con 3

 – power output for controller power cable connection. 

 

Note: 

For some models of splitters output voltage is chosen with the switcher. Operating 
with 

PERCo

 equipment it is necessary to turn the switcher into 

“12V”

 mode. 

Requirements for connecting devices 

The characteristics of power consumption of the controller when connected through splitter 
should meet the following requirements: 

Admissible value of supply voltage .............................................................. 12±1.2 V 
Minimum total current ............................................................................ min. 120 mA 
Maximum total current consumption (12V) ................................................... max 1 A 
Maximum total power consumption  ........................................................... max 12 W 

In order to avoid exceeding the total power consumption is not recommended to provide 
power from the controller to connected optional equipment (siren, passage sensors, etc.) 
and controllers of the second level. The controller powered from the splitter can be 
connected up to four readers and OD (Table 10). 

Table 10. OD with power connection through 

PoE

-splitter 

Types of controller configurations 

OD 

“Controller to operative to control the 

locks” 

Electromechanical lock (

LC, LB 

and 

LBP

-series – up to 4pcs). 

“Controller to operate the turnstile” 

Turnstile with power consumption 

no more than 9W 

T-5 

TTR-04.1 
TTD-03.1 
TTD-03.2

 

47 

Summary of Contents for CT/L-04.2

Page 1: ...Controller CT L 04 2 ASSEMBLY AND OPERATION MANUAL...

Page 2: ...Controller CT L 04 2 Assembly Operation Manual...

Page 3: ...Installation order 20 8 2 1 Controller installation 20 8 2 2 Door control configuration 22 8 2 3 Turnstile and electromechanical gates configuration 24 8 2 4 Vehicle checkpoint configuration 26 8 2 5...

Page 4: ...aims to provide correct operation of the controller and complete use of its technical capabilities The Manual contains data on installation and maintenance and also a reference section The Manual is a...

Page 5: ...k that supports two way passage Up to four electromagnetic or electromechanical locks that support one way passage One turnstile or gate One boom barrier or an automatic gate of vehicle checkpoint Bes...

Page 6: ...e Appendix 5 Clause 3 4 50 000 cards and 230 000 events by default 40 000 cards and 390 000 events 30 000 cards and 550 000 events 20 000 cards and 710 000 events 10 000 cards and 870 000 events Numbe...

Page 7: ...Certificate 1 Operation manual 1 4 2 Optional equipment Power supply 1 WRC kit 1 1 PoE splitter2 1 Siren 1 CL 201 lock controllers up to 8 AU 05 system time display 1 1 WRC kit consists of a receiver...

Page 8: ...ftware through Ethernet On default the controller has unique MAC address specified in the certificate and on the item board IP address specified in the certificate and on the item board Subnet mask 25...

Page 9: ...ing of the protected zone sending of alarm notifications to central surveillance panel 5 2 Controller boards The controller includes two boards top board processor module and bottom board process exec...

Page 10: ...input IN 9 LdA Output 7 Output for indication of direction A on the RC panel or Additional output OUT 7 TTL level LdSt Output 8 Output for indication STOP on the RC panel or Additional output OUT 8 TT...

Page 11: ...5 2 XP8 1 XP8 2 connectors in pairs to select the type of connected lock see Section 8 2 2 jumpers pair are removed if a standard electromechanical or electromagnetic lock is connected to the correspo...

Page 12: ...at next turn on if jumper is not installed Table 2 Jumper installation on XP1 connector Jumper position on XP1 Method of specifying IP addresses 1 User mode 2 IP MODE 3 IP DEFAULT 5 4 Controller conf...

Page 13: ...two alarm lines 21 The controller to operate one two way lock and one one way lock without alarm lines 22 The controller to operate one two way lock and one one way lock with one alarm line 23 The co...

Page 14: ...ce with resistance of the connection cable max 300 Ohm Control element of circuit with open drain output should provide following characteristics of signals Voltage at the closed contact low level sig...

Page 15: ...e parameter or till the moment of passage In case OD is set into Open mode relay output is activated till the mode change In pulse mode of OD In case of single passage relay output is activated for a...

Page 16: ...board in the position 1 2 see Figure 1 on the connecting block XP10 with configuration 1 AL on the connecting blocks XP9 and XP10 with configuration 2 ALs 5 7 1 Standard input configuration Jumper XP9...

Page 17: ...ce Configuration Security Less than 2 kOhm Violation short circuit 2 4 kOhm 7 kOhm Normal More than 9 kOhm Violation line break Configuration Security with tamper evidence examination of detectors hou...

Page 18: ...d devices of the communication line it is necessary to remove the jumper by cord disconnection of end of line resistor The position of jumper is indicated in the operational documentation of a specifi...

Page 19: ...n manual and safety rules Installation should be performed in accordance with general electrical and work safety rules Attention All connections and jumper installations should be carried out only whe...

Page 20: ...t allowed to lay power cables for lock sensor cables remote control cables and reader cables at a distance more than 1 m from ground cables Table 6 Cables used for installation Equipment Cable length...

Page 21: ...package contents according to Sect 4 Make sure that the equipment is not mechanically damaged 2 Define the place for installation of the controller Location of the controller should comply with operat...

Page 22: ...CT L 04 2 Controller Figure 3 Common scheme of connections 21...

Page 23: ...ment Sect 8 2 8 Note Installation order of external verifying devices to the controller is described in Appendix 2 an example of the alcohol detection device 8 2 2 Door control configuration When you...

Page 24: ...oc of lower board Figure 5 The door sensor with the lock controlled by OUT1 is connected to IN1 input OUT2 to IN2 etc The door sensor must be mounted that when the door is closed the sensor can always...

Page 25: ...e turnstile the gate to controller 1 To dissipate static electricity is recommended to ground the housing of turnstile It is necessary to use the cable with cross section minimum 0 75 mm 2 Connect the...

Page 26: ...CT L 04 2 Controller Figure 6 Connection schemes of Turnstile control configuration 25...

Page 27: ...ation from vehicle checkpoint is performed via one relay When passage is allowed OUT1 relay is activated and held sending Open signal After a vehicle has passed through the checkpoint detected by pass...

Page 28: ...CT L 04 2 Controller Figure 8 Connection scheme of boom barriers to the controller of vehicle checkpoint Figure 9 Connection scheme of passage sensors 27...

Page 29: ...ention To ensure correct passage detection of a vehicle with a trailer or other parts transparent for passage sensors it is recommended to install several spaced apart sensors or to set value of Recov...

Page 30: ...he controller FA contacts FA and GND of XT2 connecting block Figures 3 5 10 If the device Fire Alarm is absent on the input should be installed jumper by cord default installation Settings for signal...

Page 31: ...inputs as AL 8 2 8 Connection of optional equipment To connect optional equipment follow the next recommendations 1 The typical connection schemes of the optional equipment are shown on Figures 12 13...

Page 32: ...CT L 04 2 Controller Figure 13 Connection scheme of optional equipment to controller inputs 31...

Page 33: ...Fix cables with plastic ties to self adhesive cable tie mount included into delivery set by installing them inside the housing of the controller Attention To connect the optional equipment with induct...

Page 34: ...ork settings of the controller can be changed to settings recommended by system administrator in the software or via the Web interface 3 Via the Web interface perform the initial configuration of the...

Page 35: ...used This program goes together with files Software to change firmware The current version of the program is available on the website of the company www perco com in the section Support Software Also...

Page 36: ...ton in the program Data name owners are stored in the program database Verification function is available if Local software with verification is installed With connection to the security system server...

Page 37: ...ng 0 2 seconds is performed yellow indicator changes his state for 0 2 seconds The state of other indicators is not changed After the access is granted indication is turned on for Unblocked state hold...

Page 38: ...eck the power source 3 Malfunction of connection lines used to connect various devices reader indication block with infrared detector lock turnstile door sensor remote control button siren etc to the...

Page 39: ...ments IP packets to the size less than 576 bytes Check settings of this equipment enlarge the size of MTU This parameter is usually specified as MaxMTU or IPMTU 5 If several variants of switching are...

Page 40: ...enance Following types and periodicity of maintenance work should be provided planned work according to the regulation 1 once per three months planned work according to the regulation 2 receiving of t...

Page 41: ...of external circuits to connecting blocks of the controller Screwdriver It should conform to the scheme of the external connections is loosen Restore connection if the wire is broken off Replace the w...

Page 42: ...er in the original package should be transported in closed freight containers or in other closed type cargo transport units The storage of the controller is allowed indoors at ambient temperature from...

Page 43: ...After card capturing the card capture reader passes the signal Card captured which the controller uses as the confirmation of permission of passage in the required direction through the OD One of addi...

Page 44: ...CT L 04 2 Controller Figure 15 Scheme of connection of the card capture reader IC 02 1 43...

Page 45: ...Assembly Operation Manual Figure 16 Scheme of connection of the card capture reader IC 05 44...

Page 46: ...direction of passage Operation of the controller with the breathalyzer is possible only after configuring it in PERCo Web software The procedure of configuration is described in the Guide of the admin...

Page 47: ...ts where the signal PASS and FAIL are removed The scheme on Figure 18 is used to connect the breathalyzer two different free inputs are used in the current configuration of the controller Figure 18 Co...

Page 48: ...able connection Note For some models of splitters output voltage is chosen with the switcher Operating with PERCo equipment it is necessary to turn the switcher into 12V mode Requirements for connecti...

Page 49: ...roller to Con2 connector of the splitter 3 Connect the power supply to Con3 connector If necessary OD can be connected to Con3 connector too Connection scheme is shown on Figure 19 plug for connection...

Page 50: ...in the system is carried out via the Ethernet interface therefore zoning control for this OD in the system will not be supported 2 As a fingerprint reader when controlling one of the directions of a d...

Page 51: ...ettings of memory allocation 54 4 CONFIGURATION 54 4 1 The choice of the controller configuration 54 4 2 Configuration of the Settings of the controller resources 55 4 2 1 Operating devices 55 4 2 2 P...

Page 52: ...onitor the configuration operations are forbidden The access to Web interface is allowed if the software is configured to Allow Web interface It is possible after stopping the operation of the softwar...

Page 53: ...go you navigate to the main page from other sections of Web interface 2 Sidebar of the Web interface navigation The panel has the following structure Network Password Time Settings Memory usage Templa...

Page 54: ...troller is not specified To change or set the new password 1 Click in the Web interface menu Settings Password The page with working area will be opened 2 In the New password field enter the new passw...

Page 55: ...allocation of the controller 1 Click in the Web interface menu Settings Memory usage The page with working area will be opened 2 In dropdown list Memory resizing select one of the variants of the memo...

Page 56: ...4 2 1 Operating devices To configure Settings of the controller resources to control OD 1 Click consistently in the Web interface menu Configuration Edit Operating devices The page with working area...

Page 57: ...ges click the Cancel button or the Close button 4 2 2 Physical contacts inputs and outputs To configure the Settings of the controller inputs and outputs 1 Click consistently in the Web interface menu...

Page 58: ...he window of physical contact without saving changes click the button Cancel Also it is possible to close the window using the Close button 4 2 3 Readers In all controller configurations for each dire...

Page 59: ...ow Reader number will be closed the reader will be removed from the list 6 To exit from the window Reader number without saving changes click the button Cancel Also it is possible to close the window...

Page 60: ...cessary changes of the Settings Selector Number sets the number of response from 1 to 40 Selector Source type specifies the launch condition of the controller response Selector Source number Receiver...

Page 61: ...menu Operating device control The page with working area will be opened 2 Click in the working area of the page on the line with OD to which it is necessary to issue the control command The control w...

Page 62: ...unavailable To enter the card identifiers 1 Click consistently in the Web interface menu Access cards Enter The page with working area will be opened 2 If necessary use the dropdown list in the headi...

Page 63: ...e transferred to the main list of the cards in section List Attention When you enter the card identifiers in the list of the controller by default they are granted rights of access over all ODs connec...

Page 64: ...tifiers Note The display format is not the format of reading of the card identifiers set in the Configuration section Clause 4 2 4 when you change the display format the format of reading does not cha...

Page 65: ...of rights to keep the status Unblocked but in the other sets to put the status Blocked 8 To delete the card click the Delete button at the bottom part of the window 9 To save changed Settings of the c...

Page 66: ...window of the Explorer specify location and name of the file with the card list and click the Open button The explorer window will be closed the file name will be indicated in the field near the Brows...

Page 67: ...nning point and Range end point to set the period of the report 6 Click the Apply button to apply the filter click the Cancel button to cancel any made changes The window Filter closes the report will...

Page 68: ...For diagnostic purposes of the controller with the previous formatting click the Start button in the line Diagnostics formatting 15 min 4 To start formatting the internal memory of the controller clic...

Page 69: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 70: ...www perco com...

Reviews: