201
5-0
3
24
Pulscon LTC57 PROFIBUS PA
Mounting
Figure 6.3
Silica sand in silo with smooth metallic walls; tensile load as a function of level L for
rope diameters 6 mm (0.24 in) and 4 mm (0.16 in)
Figure 6.4
Polyethylene pellets in silo with smooth metallic walls; tensile load as a function of
level L for rope diameters 6 mm (0.24 in) and 4 mm (0.16 in)
A
Silo diameter 12 m (40 ft)
B
Silo diameter 9 m (30 ft)
C
Silo diameter 6 m (20 ft)
D
Silo diameter 3 m (10 ft)
A
Silo diameter 12 m (40 ft)
B
Silo diameter 9 m (30 ft)
C
Silo diameter 6 m (20 ft)
D
Silo diameter 3 m (10 ft)
0
5
10
15
20
25
30
35
0
10
20
30
40
50
60
F
[kN]
6m
m
L [m]
F
[kN]
4m
m
0
4
8
12
16
20
24
28
32
36
40
A
B
C
D
F
[kN]
6m
m
L [m]
F[
k
N
]
4m
m
0
5
10
15
20
25
30
35
A
B
C
0
2
4
6
8
10
12
14
16
18
0
2
4
6
8
10
12
D