Table 8: Status screen descriptions, values, and selections
Screen name
Description
Value or
selection
SN1: HIGH
TEMP ALARM
Conditional
screen
This screen displays the status of the SN1 high temperature
alarm. The alarm condition is true if the temperature of SN1
is above the threshold value for a period of time greater than
or equal to the alarm delay.
•
YES
•
NO
SN1: LOW TEMP
ALARM
Conditional
screen
This screen displays the status of the SN1 low temperature
alarm. The alarm condition is true if the temperature of SN1
is below the threshold value for a period of time greater than
or equal to the alarm delay.
•
YES
•
NO
SN3: HIGH
TEMP ALARM
Conditional
screen
This screen displays the status of the SN3 high temperature
alarm. The alarm condition is true if the temperature of SN3
is above the threshold value for a period of time greater than
or equal to the alarm delay.
You can only enable this alarm if you configure SN3 as a case
sensor.
•
YES
•
NO
SN3: LOW TEMP
ALARM
Conditional
screen
This screen displays the status of the SN3 low temperature
alarm. The alarm condition is true if the temperature of SN3
is below the threshold value for a period of time greater than
or equal to the alarm delay.
You can only enable this alarm if you configure SN3 as a case
sensor.
•
YES
•
NO
SN1: FAILURE
ALARM
Conditional
screen
This screen displays the status of the SN1 failure alarm.
The alarm condition is true if a very high or very low level is
detected.
•
YES
•
NO
SN2: FAILURE
ALARM
Conditional
screen
This screen displays the status of the SN2 failure alarm.
The alarm condition is true if a very high or very low level is
detected.
•
YES
•
NO
SN3: FAILURE
ALARM
Conditional
screen
This screen displays the status of the SN3 failure alarm.
The alarm condition is true if a very high or very low level is
detected.
•
YES
•
NO
DOOR OPEN
ALARM
Conditional
screen
This screen displays the status of the door open alarm. The
alarm condition is true if the door has remained open for a
period of time greater than or equal to the alarm delay.
•
YES
•
NO
MR5 Series Panel Mount Case Controller Technical Bulletin
24