SERVICING
91.
DO NOT MODIFY THIS APPLIANCE
Service only to be carried out by an authorized person.
Turn the appliance OFF and isolate the gas supply. Ensure the appliance is fully cold before attempting to
start servicing the appliance. No liability can be accepted by Living Fire for injury caused by burning or
scolding by a hot appliance.
A suggested procedure for servicing is listed below.
1. Lay out dust sheet on flooring, mask off any special fireplace materials.
2. Remove Outer Glazing Panel
3. Remove Bottom Window Trim
4. Remove Inner Window Panel
5. Carefully remove the Ceramic components (including Embers) or Gravels
6. Use a Vacuum cleaner to clean the top of the burners and grate
7. Remove Grate
8. Using a vacuum cleaner, fully clean both Burner Top.
9. Use the vacuum cleaner and a soft brush to clean the pilot assembly and Injectors. Never modify or
bend the Thermocouple
10. Turn on the gas supply and check for leaks, check the burners and Pilot for good condition and
operation
11. Replace Grate
12. Replace the Fire bed arrangements
13. Replace Window Assemblies and Trims
14. Check the flue system and terminal, making sure that the terminal vent is fully clear
15. Light the appliance and test setting pressures
16. Check the safe operation of the appliance.
Aerion Range
Summary of Contents for Aerion Series
Page 7: ...PRODUCT DIMENSIONS 2 G1410 GF G1410 GF2L Aerion Range...
Page 8: ...PRODUCT DIMENSIONS 3 G1410 GF2R GF1410 GF3 Aerion Range...
Page 9: ...PRODUCT DIMENSIONS 4 G1410 RD G1410 T Aerion Range...
Page 10: ...PRODUCT DIMENSIONS 5 G1250 GF GF1250 GF2L Aerion Range...
Page 12: ...PRODUCT DIMENSIONS 7 G800 GF G800 T Aerion Range...
Page 13: ...PRODUCT DIMENSIONS 8 G650 Aerion Range ALTO GF...
Page 14: ...PRODUCT DIMENSIONS 9 ALTO T Aerion Range...
Page 22: ...17 Aerion Range UNIT TO TV CLEARANCES COMBUSTIBLE MANTLE Figure 1 4 Clearance from Unit to TV...
Page 104: ...Distributed By LIVING FIRE 61 3 99 777 888 info livingfire com au www livingfire com au...