82.
MAIN BURNER CHECK
Aerion Range
1.
Ignite the pilot light as described in the User Instructions
2.
Turn on the main burner as described in the User Instructions
3.
Check that the pilot smoothly cross-lights to the main burner and that the main burner
and pilot stay alight
4.
Check the operation of the second "effect" burner as described in the User Instructions
5.
Extinguish the appliance fully
Pressure check
Always check the inlet pressure and burner pressure.
Apparatus and tools needed to check the outlet gas valve gas pressures.
•
1 x Pressure manometer digital
•
Flat (4 mm wide) bladed screw driver for adjusting * PTP
•
Flat (2 mm wide) bladed screw driver for access to HI fire out (burner) pressure adjustment
•
4 mm Allen key for access to LO fire pressure adjustment
Pressure check with gas valve installed in the control hatch.
The Mertik GV 60 gas valve and receiver/ignition module are located in the control hatch. The
GV
60 gas valve is secured into the control hatch housing via (a) a male tab inserted into a slot
in the
top mounting bracket and (b) a threaded rod with a head to accept a 4 mm Allen key (
Ȼ
rear of
gas valve) secured into a mounted bracket.
(a)
(b)
The pressure test points for the inlet and outlet (burner) pressure measurements are located at
the top of the gas valve casing.
Loosen the screw counter clockwise on the outlet pressure test point on the gas valve and
connect a manometer to the * PTP
–
refer above marked with the
red
arrow.
*
PTP = pressure test point.
Summary of Contents for Aerion Series
Page 7: ...PRODUCT DIMENSIONS 2 G1410 GF G1410 GF2L Aerion Range...
Page 8: ...PRODUCT DIMENSIONS 3 G1410 GF2R GF1410 GF3 Aerion Range...
Page 9: ...PRODUCT DIMENSIONS 4 G1410 RD G1410 T Aerion Range...
Page 10: ...PRODUCT DIMENSIONS 5 G1250 GF GF1250 GF2L Aerion Range...
Page 12: ...PRODUCT DIMENSIONS 7 G800 GF G800 T Aerion Range...
Page 13: ...PRODUCT DIMENSIONS 8 G650 Aerion Range ALTO GF...
Page 14: ...PRODUCT DIMENSIONS 9 ALTO T Aerion Range...
Page 22: ...17 Aerion Range UNIT TO TV CLEARANCES COMBUSTIBLE MANTLE Figure 1 4 Clearance from Unit to TV...
Page 104: ...Distributed By LIVING FIRE 61 3 99 777 888 info livingfire com au www livingfire com au...