59.
FLUEING INFORMATION
90° elbow 45° bend
Elbows and bends create resistance within the venting
configuration, and they must be included when determining
the minimum and maximum fluing lengths. There must
be an absolute minimum vertical rise of 600 mm before
any elbow but preferably a vertical rise of 900 mm is
recommended. Maintain the maximum length of straight
flue between elbows or bends.
The use of a 90° elbow is equal to 0.5 metres in flue length
and the 45° bend is equal to 0.25 metres in flue length i.e.,
if one 90° elbow is used then the total maximum flue length
is reduced to 5.5 metres.
No more than two (2) 90° elbows or four (4) 45° bends can
be used in the flue configuration.
Termination cap. The same basic termination (cowl) cap
is used for both vertical and horizontal installations.
For the vertical installation the terminal is fitted with a wind
guard. For horizontal installation the terminal is not fitted
with a wind guard.
30 mm down from the hood. Note: THIS TERMINAL
MUST ALWAYS VENT DIRECTLY TO OUTDOORS.
Aerion Range
Summary of Contents for Aerion Series
Page 7: ...PRODUCT DIMENSIONS 2 G1410 GF G1410 GF2L Aerion Range...
Page 8: ...PRODUCT DIMENSIONS 3 G1410 GF2R GF1410 GF3 Aerion Range...
Page 9: ...PRODUCT DIMENSIONS 4 G1410 RD G1410 T Aerion Range...
Page 10: ...PRODUCT DIMENSIONS 5 G1250 GF GF1250 GF2L Aerion Range...
Page 12: ...PRODUCT DIMENSIONS 7 G800 GF G800 T Aerion Range...
Page 13: ...PRODUCT DIMENSIONS 8 G650 Aerion Range ALTO GF...
Page 14: ...PRODUCT DIMENSIONS 9 ALTO T Aerion Range...
Page 22: ...17 Aerion Range UNIT TO TV CLEARANCES COMBUSTIBLE MANTLE Figure 1 4 Clearance from Unit to TV...
Page 104: ...Distributed By LIVING FIRE 61 3 99 777 888 info livingfire com au www livingfire com au...