INSTALLATION INSTRUCTIONS
Firebox access, control hatch relocation and clearance spacer bracket installation
All Living Fire gas space heaters are double glazed for your protection and to maximise the luxury appearance. Carefully
follow steps below to remove glass panels in order to access the firebox prior to media installation.
Removal/installation arrangements for glass panel/s. Common to all models.
Removal of control hatch from the transit bracket
Before commencing installation, confirm that the
details on the heater data label correspond to the
local distribution conditions, gas type and pressure
for which the heater is to be installed. The data label
(and other essential labelling) is adhered to the rear
of the door of the control hatch.
Step 1: Remove the protective material from
around the control hatch.
There are four transit screws (each side) securing
the control hatch to the transit bracket. With a
Phillips head screwdriver remove the 4 screws LH/
RH side securing the control hatch to the transit
bracket, Before, removing the last screw, support the
bottom of the control hatch, remove the last screw,
and lay the control hatch on the protective material
to protect against damage to the powder coating.
Step 2: There are two bolts on each side securing
the transit bracket to the chassis. With a 10 mm
spanner or 10 mm nutsert remove the bolts from
the bracket and discard. Ensure that the gas supply
and supply pipe is capable of delivering the required
volume and pressure of gas and is in accordance
with AS/NZS 5601.1
1.1 Gas Connection: This heater has a
gas inlet connection of 3/4” BSP with a flat for
spanner engagement. The gas inlet connection is
accessible via the control hatch. The fitment of a
gas isolation valve prior to the gas inlet connection
is recommended. Prior to connecting the gas inlet
supply ensure the gas line is purged. With the
control hatch surround in position and the hatch door
removed – secured hatch surround flange onto the
front face of the enclosure. The gas inlet connection
is accessible below the gas control. Connect the
incoming gas supply line onto the 3/4” BSP fitting
whilst engaging a spanner onto the inlet connection
flat. When the connection has been made check for
gas tightness.
Summary of Contents for Aerion Series
Page 7: ...PRODUCT DIMENSIONS 2 G1410 GF G1410 GF2L Aerion Range...
Page 8: ...PRODUCT DIMENSIONS 3 G1410 GF2R GF1410 GF3 Aerion Range...
Page 9: ...PRODUCT DIMENSIONS 4 G1410 RD G1410 T Aerion Range...
Page 10: ...PRODUCT DIMENSIONS 5 G1250 GF GF1250 GF2L Aerion Range...
Page 12: ...PRODUCT DIMENSIONS 7 G800 GF G800 T Aerion Range...
Page 13: ...PRODUCT DIMENSIONS 8 G650 Aerion Range ALTO GF...
Page 14: ...PRODUCT DIMENSIONS 9 ALTO T Aerion Range...
Page 22: ...17 Aerion Range UNIT TO TV CLEARANCES COMBUSTIBLE MANTLE Figure 1 4 Clearance from Unit to TV...
Page 104: ...Distributed By LIVING FIRE 61 3 99 777 888 info livingfire com au www livingfire com au...