6.2 Function Codes Switchover in/between Code-Groups
It has more than 300 parameters (function codes) available to user, divided into sections as
indicated in Table 6-3.
Table 6-3 Function Code Partition
Group Name
Function
Code Range
Group
No.
Group Name
Function
Code Range
Group
No.
Basic Parameters
F100
~
F160
1
Timing control and
protection
function
F700
~
F770
7
Run Control Mode
F200
~
F280
2
Parameters of the
motor
F800
~
F850
8
Multi-functional
input/output terminal
F300
~
F340
3
Communication
function
F900
~
F930
9
Analog signals and
pulse of input/output F400
~
F480
4
PID parameter
setting
FA00
~
FA80
10
Multi-stage speed
Parameters
F500
~
F580
5
Torque control
FC00~FC40
11
Subsidiary function F600
~
F670
6
As parameter setting can take time due to numerous function codes, such function is specially
designed as “Function Code Switchover in a Code Group or between Two Code-Groups” so
that parameters setting becomes convenient and simple.
Press “M” key so that the keypad controller will display function code. If user presses “▲” or “▼”
key, the function code will circularly keep increasing or decreasing by degrees within the group;
if user presses the
key again, the function code will change circularly between two code
groups when operating the “▲” or “▼” key.
F1-00 is displayed,
the last
“
0
”
in
F1-00 is flashing.
F1-00~F1-60 can be
displayed.
▲
or
▼
key
Press
key
Press
▲
or
▼
key
Currently showing
50.00
Press M key
1 in F1-00 is
flashing.
Press
F1-00~FC-00 can be
displayed.