6-1
The Menu Organisation
AC10 Inverter
Chapter 6
The Menu Organisation
All keys on the panel are available for user. Refer to Table 6-1 for their functions.
Table 6-1 Uses of Keys
Keys
Names
Remarks
Menu
To call function code and switch over display mode.
sEt
To call and save data.
Up
To increase data (speed control or setting parameters)
Down To decrease data (speed control or setting parameters)
Run To start inverter;
Stop or
reset
To stop inverter; to reset in fault status;
Forward
or
reverse
Switchover between forward and reverse.
Shift key Shift and displaying items switchover
Multi-fun
ctional
key
FWD/REV jogging and local/remote can be selected by
multi-functional key, please refer to F643.
6.1 Parameters Setting
This inverter has numerous function parameters that the user can modify to effect different
modes of operation. The user should be aware that if they set password valid (F107=1), the
password must be entered first if parameters are to be set after power off or protection is
effected, i.e., to call F100 as per the mode in Table 6-2 and enter the correct code. User’s
password is invalid before delivery, and user could set corresponding parameters without
entering password.
Table 6-2 Steps for Parameters Setting
Steps
Keys
Operation
Display
1
Press “M” key to display function code
2
or
Press “Up” or “Down” to select required function code
3
Read data set in the function code
4
or
To modify data
5
Shows corresponding target frequency by flashing
after saving the set data
Displays the current function code
The above-mentioned step should be operated when inverter is in stop status.