8. Various settings
WMD078TE0PAA07
97
W
eld
in
g c
ur
re
nt
u
pp
er
/lo
w
er
lim
it d
et
ec
tio
n
Welding current lower
limit detection set value
(%)
Note
Lower limit=Preset
value-(Preset value x
Adjustment value)
Eg.
)Preset value: 100 A,
Adjustment value: 10 %
⇒
Lower limit = 90 A
23
WELD(A) L-LIMIT
0 to 100
1
0
Contact output at weld-
ing current upper/lower
limit detection ON/OFF
24
WELD(A) DET CONTACT
0: OFF
1: ON
-
0
Motion at welding cur-
rent upper/lower limit
detection
25
WELD(A) DET MOVE
0: Continue (Indica-
tion only)
1: Stop at the end
of the current
welding. Then
press ENTER but-
ton to reset.
-
0
W
eld
in
g v
olt
ag
e u
pp
er
/lo
w
er
lim
it d
et
ec
tio
n
Welding voltage upper/
lower limit detection
ON/OFF
30
WELD(V) MONITOR
0: OFF
1: ON
-
0
Welding voltage upper/
lower limit detection
time (s)
31
WELD(V) DETECT T
0.1 to 99.9
0.1
1.0
Welding voltage upper
limit detection set value
(%)
Note
Upper limit=Preset
value + (Preset value x
Adjustment value)
Eg.)Preset value:18.4 V,
Adjustment value: 10 %
⇒
Upper limit: 20.2 V
32
WELD(V) UP-LIMIT
0 to 100
1
0
Welding voltage lower
limit detection set value
(%)
Note
Lower limit=Preset
value-(Preset value x
Adjustment value)
Eg.
)Preset value: 18.4 V,
Adjustment value: 10 %
⇒
Lower limit: 16.6 V
33
WELD(V) L-LIMIT
0 to 100
1
0
Contents
Sub-
menu
No.
LCD display (1st line)
Setting range
Incre-
ment
Default
Output management function