8. Various settings
WMD078TE0PAA07
83
Wire feed fine adjust-
ment
(*1)
11
WFS FINE ADJ
-50 to 50
1
0
Wave control1
(*1)
13
WAVE CONTROL 1
-99 to 99
1
0
Pulse frequency
(*2)
14
PULSE FREQ
-99 to 99
1
0
Fine tune of pulse peak
ON time
17
PULSE WIDTH
-99 to 99
1
0
No crater pulse
18
CRATER DC
0: Invalid
1: Valid
-
0
No initial pulse
19
INIT PLS DC
0: Invalid
1: Valid
-
0
Low pulse setting
(*1)
20
LOW PULSE SET
0: Invalid
1: Valid
2: Automatic
(*3)
-
0
(*1)
Low pulse level: Current
21
LOW PULSE CUR
30 to 400
2
120
(*1)
Low pulse level: Voltage
22
LOW PULSE VOL
5 to 50
0.2
20.2
Low pulse frequency
(*1)
23
LOW PULSE FREQ
0.5 to 10
0.1
2.0
Low pulse A-B ratio
(*1)
24
LOW PULSE DUTY
10 to 90
5
50
Low pulse delay time
(*1)
25
LOW PUOLSE DELAY
0 to 9.9
0.1
0
Result display time (sec-
ond)
30
DISPLAY TIME
1 to 30
1
5
(*1)
Control of penetration
increase
32
PENET INC
0: Invalid
1: Valid
2: Automatic
-
2
(*1)
Terms are described later in this section.
(*2)
”Pulse frequency” is not adjustable if the material is set to “AL-HARD (hard aluminum)” or
“AL-SOFT (soft aluminum)”.
(*3)
When “Low pulse setting” is set to “2. Automatic”, the “Low pulse delay time” becomes “0” and
cannot be adjusted.
(*4)
Applicable only
to “
PULSE [OFF]
” setting.
Set item
Submenu #
LCD display (1st line)
Setting range
Increment
Default