3. Installation
WMD078TE0PAA07
12
3. Installation
3.1 Installation site
(1) Locate indoors only, where the floor is
capable of supporting the weight of the
product.
(2) Avoid exposure to the direct sun light or
the rain or water spray.
<Note> If exposed to the rain or water
spray, or dew condensation occurred, dry
the product before using it.
(3) Ambient temperature
(a)
During welding operation: -10 °C to 40 °C
(b)
During transportation/storage: -20 °C to
55 °C
(4) Humidity relative to temperature
(a)
Up to 50 % at 40 °C.
(b)
Up to 90 % at 20 °C.
(5) Altitude above sea level: Up to 1000 m.
(6) Spacing
(a) From the wall: 200 mm or more.
(b) Between welders installed side-by-side:
300 mm or more.
(7) Avoid wind to the arc. (Provide wind-
shields.)
(8) Free from abnormal amounts of dust, acid,
corrosive gases or substances etc. other
than those generated by the welding pro-
cess.
(9) Avoid places where the metallic substances
or combustible foreign materials can get
into the welder through the air inlets.
(10)
Inclination to installation surface: Max 10°.
<Note> When installing the product on a
inclined surface, make sure to scotch the cast-
ers. Or the casters to move unexpectedly.
(11) Do not place the product rear-side down or
side-surface down to use. Placing the product
in such manner will reduce the cooling effect
of the machine, which will cause the malfunc-
tion or burnout of the machine. (See the fig-
ure on the right.)
Attention
================================
When the product is installed on the floor
where it is too low to operate, customers
are required to prepare a table to mount
the product on. Such table should be pro-
vided with flanges on the mounting surface
to prevent the product to slide off the
table.
お願い
========================================
====
50
0
40 °C
-10 °C
300 mm
200 mm
W
eld
er
W
eld
er
or more
or more
W
eld
er
W
el
de
r