8. Various settings
WMD078TE0PAA07
78
No.
Contents
LCD
Set value
Setting range
1 Select joint type
JOINT SELECT
-> 1.FILLET?
001
1.FILLET
002
2.LAP
003
3.BUTT
2
(*2)
Thickness1 (mm)
THICKNESS1
-> (Minimum)
(*1)
mm
?
(Minimum)
(*1)
0.8 to 12.0
(*3)
(Increment: 0.1)
rEt
Return (go to previous setting
item)
3
(*2)
Thickness2 (mm)
THICKNESS2
-> (Minimum)
(*1)
mm
?
(Minimum)
(*1)
0.8 to 12.0
(*3)
(Increment: 0.1)
rEt
Return (go to previous item)
4 Welding speed
(m/min.)
WELDING SPEED
-> (Minimum)
(*1)
m/min
?
(Minimum)
(*1)
0.2 to 1.0
(*3)
(Increment: 0.1)
rEt
Return (go to “THICKNESS1” setting)
(*1)
Minimum: the smallest value of the setting range of material, wire diameter or gas.
(*2)
Thickness1, Thickness2: Thickness of
workpieces to be welded.
*No particular order.
(See the figure on the right.)
(*3)
Setting range for thickness varies with
material, wire diameter and gas settings.
Panasonic
VP1 series
Indicates set value.
Dial1
Dial2
ENTER button
Submenu number
・
Use Dial1 to select.
・
Press ENTER to set.
Set value
・
Use Dial2 to select.
・
Press ENTER to set.
Thickness1
Thickness2