8. Various settings
WMD078TE0PAA07
105
Contents
Submenu#
LCD display (1st line)
Setting range
Incre-
ment Default
Output value correction: OFF-
SET (A)
11
OFFSET
-20 to 20
1
0
Fill flow time (second)
12
FILL FLOW TIME
0
to
60
ー
0
Current detection delay (ms)
13
CURR DET DELAY
0
to
300
1
50
IIF unit function
(* Not applicable to this
product.)
14
IIF FUC SEL
0: CH63+Retract
1: CH100
ー
0
Time setting
15
DATE/TIME
-
ー
ー
Select language
16
LANGUAGE
0:
1: English
ー
1
Crater repeat expiration (sec-
ond)
17
CRATER REP TIME
0.5 to 5.0
0.1
2.0
Reset items
(Whether to reset welding
parameters/memory chan-
nels (RECORD mode).
18
RESET
0: ADVANCED
1: DETAI+MEMORYCH
2: RETURN
ー
ー
(Not in use)
19
OPT. COND. UNIT
0: OFF
1: ON
ー
0
Specify voltage detection
method
20
VOLT. DETECT
0: Normal TERM
1: External TERM
ー
0
(*)
: When the digital remote controller is connected, set to “
0: Without
”.
Panasonic
VP1 series
Dial 1
Dial 2
ENTER button
Indicates set value
Submenu number
・
Use Dial1 to select.
・
Press ENTER to set.
Set value
・
Use Dial2 to select.
・
Press ENTER to set.