8. Various settings
WMD078TE0PAA07
85
Impulse start
81
IMPULSE START SW
0: Invalid
1: Valid
2: Automatic
ー
2
End pulse settings
83
ENDPLS
0: Invalid
1: Valid
2: Automatic
ー
2
Burnback2
84
BURNBACK 2
0: Invalid
1: Valid
ー
0
Initial condition: Cur-
rent
88
INIT COND CUR
-50 to 50
2
0
Initial condition: Volt-
age
89
INIT COND VOL
-50 to 50
2
0
Initial condition: Time
90
INIT COND TIME
-99 to 99
1
0
Initial start slope
91
INIT START SLOP
-99 to 99
1
0
Initial down slope
92
INIT DOWN SLOP
-99 to 99
1
0
Initial current limit
93
INIT LIMIT CUR
-50 to 50
2
0
Crater condition: Cur-
rent
94
CRAT COND CUR
-50 to 50
2
0
Crater condition: Volt-
age
95
CRAT COND VOL
-50 to 50
2
0
Crater condition: Time
96
CRAT COND TIME
-99 to 99
1
0
Crater down time
97
CRAT DOWN SLOP
-99 to 99
1
0
Crater skip time
98
CRAT SKIP TIME
-99 to 99
1
0
(*1)
CDM(Current Detect Mask): It reduces wire feed speed at arc start.
Set item
Submenu #
LCD display (1st line)
Setting range
Incre-
ment
Default