8. Various settings
WMD078TE0PAA07
123
8.10.2 PULSE PEAK CURRENT
It fine-tunes the pulse peak current in pulse weld-
ing.
* It is the same setting contents as Submenu 07
of the GROUP 1 in DETAIL mode. See section
” on page
1
.
Select WELD mode.
Press mode SELECT button sev-
eral times until LED for WELD is
lit.
* SET button is enabled only in
WELD mode.
2 Select PULSE PEAK CURRENT.
Press SET button a few times until
LED for PULSE PEAK CURRENT is
lit.
3 Fine-tune the pulse peak current.
Use Dial2 to adjust.
→
Display2 indicates the pulse
peak current set value. (Dis-
play1 indicates the current set
value.)
4 Press ENTER button.
mode SELECT button
Panasonic
VP1 series
Dial2
ENTER button
Display2
LCD
SET button
溶接
溶接ナビ
詳細
再生
記憶
選択
Diplay2
Pulse peak current set value
PULSE PEAK CUR
-
LCD