5. Names and functions
WMD078TE0PAA07
29
No.
Name
Functions
Control process indica-
tor
It indicates control process.
•
Specified combination of LEDs are lit according to the control
process
(“No crater”, “Crater” or “Ini.&Crater”) set by [CONTROL]
button (
).
•
If the [ARC SPOT] button (
) is pressed to use the arc spot, only
the LED for [MAIN] (
) is lit.
•
When [INITIAL] (
), [MAIN] (
) or [CRATER](
) button is
pressed to change conditions, corresponding LED blinks.
Arc spot indica-
tor&button
Use it to set arc spot.
•
LED is off: No Arc spot
•
LED is on: Arc spot is applicable
(Then, LED (
) for [MAIN] (
) is turned on.)
Operation lock indica-
tor&button [LOCK]/
Enter button [ENTER]
Use it to lock the operation.
•
Long press of the button lights the LED above the button and locks
the operation.
•
Long pressing again to turn off the LED and release the lock state.
•
While locking the operation, all buttons and dials except GAS-
CHECK (
) and INCHING (
) buttons do not function.
When Mode indicator (
) “WELD” is lit:
•
The button is disabled.
When Mode indicator (
) “WELD
NAVI.
77) is lit:
•
Use it to set the condition of the selected joint shape, thickness and
wire feed speed.
When Mode indicator (
) “DETAIL” (see page
82) is lit:
•
Use it to set the selected group number and submenu number.
•
Use it to set the specified set value.
9
12
11
13
28
29
22
12
13
7
8
10
11
11
[
INITIAL
]
[
MAIN
] [
CRATER
]
7
12
9
8
9
10
12
ARC SPOT
11
9
13
ENTER
LOCK
(HOLD)
28
29
22
22
22