2-35
Chapter 2 Maintenance
(Fig. 1) j0mf42049
Adjustment
Procedure
1.
Release the DADF and loosen the Screws. (Fig. 2)
(1) Loosen the Screw (2).
(Fig. 2) j0mf42050
2.
Close the DADF and adjust the Gap between the Platen Glass Side Guide and the Platen
Belt Assembly using the adjusting Screw. (Fig. 3)
(Fig. 3) j0mf42051
3.
Open the DADF and tighten the Screws. (Fig. 4)
(1) Tighten the Screw (2).
(Fig. 4) j0mf42050
4.
Repeat the checking and make sure that the height is correct.
The steps for the left and right sides are the same.
• Rotate in the A direction -> Approx. 0.75 mm lower
• Rotate in the B direction -> Approx. 0.75 mm higher