3-261
Chapter 3 Troubleshooting
[Description]: DC VBias value
104.752-474
[NVM Name]: Flag Empty Detection Status [Y]
[PSW Display]: Flag Empty Detection Status [Y]
[Initial Value]: 0
[Setup Range]: 0~3
[Description]: Flag of Empty status (0: Normal 1: In Empty Count 2: Near Empty 3:
End)
105.752-475
[NVM Name]: Flag Empty Detection Status [M]
[PSW Display]: Flag Empty Detection Status [M]
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
Flag of Empty status (0: Normal 1: In Empty Count 2: Near Empty 3: End)
106.752-476
[NVM Name]: Flag Empty Detection Status [C]
[PSW Display]: Flag Empty Detection Status [C]
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
Flag of Empty status (0: Normal 1: In Empty Count 2: Near Empty 3: End)
107.752-477
[NVM Name]: Flag Empty Detection Status [K]
[PSW Display]: Flag Empty Detection Status [K]
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
Flag of Empty status (0: Normal 1: In Empty Count 2: Near Empty 3: End)
108.752-496
[NVM Name]: Nominal value for NEAR Detection [Y]
[PSW Display]: Nominal value for NEAR Detection [Y]
[Initial Value]: 625
[Setup Range]: 0~32767
[Description]: Count threshold for Near Detection
109.752-497
[NVM Name]: Nominal value for NEAR Detection [M]
[PSW Display]: Nominal value for NEAR Detection [M]
[Initial Value]: 625
[Setup Range]: 0~32767
[Description]: Count threshold for Near Detection
110.752-498
[NVM Name]: Nominal value for NEAR Detection [C]
[PSW Display]: Nominal value for NEAR Detection [C]
[Initial Value]: 625
[Setup Range]: 0~32767
[Description]: Count threshold for Near Detection
111.752-499
[NVM Name]: Nominal value for NEAR Detection [K]
[PSW Display]: Nominal value for NEAR Detection [K]
[Initial Value]: 625
[Setup Range]: 0~32767
[Description]: Count threshold for Near Detection
112.752-784
[NVM Name]: Failure Disp Unusual [Y]
[PSW Display]: Failure Disp Unusual [Y]
[Initial Value]: 0
[Setup Range]: 0~1
[Description]:
Failure when new Toner Cartridge is installed and the Disp Motor Drive did not
shift from new to old. 0: Normal 1: Error
113.752-785
[NVM Name]: Failure Disp Unusual [M]
[PSW Display]: Failure Disp Unusual [M]
[Initial Value]: 0
[Setup Range]: 0~1
[Description]:
Failure when new Toner Cartridge is installed and the Disp Motor Drive did not
shift from new to old. 0: Normal 1: Error
114.752-786
[NVM Name]: Failure Disp Unusual [C]
[PSW Display]: Failure Disp Unusual [C]
[Initial Value]: 0
[Setup Range]: 0~1
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......