3-278
Chapter 3 Troubleshooting
Adjusts the Fast Scan direction write start position by Switching the Video Lock
position phase from SOS Signal. (4 Colors/Correction Resolution Ability: 1 Pixel
unit)
36. 760-051
[NVM Name]: XBI-C
[PSW Display]: C-XBI
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
Adjusts the Fast Scan direction write start position by Switching the Video Lock
position phase from SOS Signal. (4 Colors/Correction Resolution Ability: 1 Pixel
unit)
37. 760-052
[NVM Name]: XBI-K
[PSW Display]: K-XBI
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
Adjusts the Fast Scan direction write start position by Switching the Video Lock
position phase from SOS Signal. (4 Colors/Correction Resolution Ability: 1 Pixel
unit)
38. 760-053
[NVM Name]: OLXSO-Y-1
[PSW Display]: Y-OLXSO
[Initial Value]: 10
[Setup Range]: 0~20
[Description]:
The normal Regi Control cycle, separately adjusts the Fast Scan direction write
start position by the No. of Video Locks from SOS signal in an Open Loop, from
the temperature detection result. (4 Colors/Correction Resolution Ability: 1 Pixel
unit)
39. 760-054
[NVM Name]: OLXSO-M-1
[PSW Display]: M-OLXSO
[Initial Value]: 10
[Setup Range]: 0~20
[Description]:
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start
position by the No. of Video Locks from SOS signal in an Open Loop, from the
temperature detection result. (4 Colors/Correction Resolution Ability: 1 Pixel unit)
40. 760-055
[NVM Name]: OLXSO-C-1
[PSW Display]: C-OLXSO
[Initial Value]: 10
[Setup Range]: 0~20
[Description]:
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start
position by the No. of Video Locks from SOS signal in an Open Loop, from the
temperature detection result. (4 Colors/Correction Resolution Ability: 1 Pixel unit)
41. 760-056
[NVM Name]: OLXSO-K-1
[PSW Display]: K-OLXSO
[Initial Value]: 10
[Setup Range]: 0~20
[Description]:
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start
position by the No. of Video Locks from SOS signal in an Open Loop, from the
temperature detection result. (4 Colors/Correction Resolution Ability: 1 Pixel unit)
42. 760-057
[NVM Name]: OLXBI-Y-1
[PSW Display]: Y-OLXBI
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
The normal Regi Control cycle, separately adjusts the Fast Scan direction write
start position by replacing the Video Locks phase from SOS signal in an Open
Loop, from the temperature detection result. (4 Colors/Correction Resolution
Ability: 1 Pixel unit)
43. 760-058
[NVM Name]: OLXBI-M-1
[PSW Display]: M-OLXBI
[Initial Value]: 0
[Setup Range]: 0~3
[Description]:
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......