3-280
Chapter 3 Troubleshooting
[Setup Range]: 0~200
[Description]:
The normal Regi Control separately adjusts the Fast Scan direction image 100 %
magnification by switching the average frequency of each LSU (ROS) Video
Lock in an Open Loop from the Temperature detection result. (4 Colors/
Correction Resolution Ability: 1/4 Pixel unit)
52. 760-067
[NVM Name]: OLMAG-C-1
[PSW Display]: C-OLMAG
[Initial Value]: 100
[Setup Range]: 0~200
[Description]:
The normal Regi Control separately adjusts the Fast Scan direction image 100 %
magnification by switching the average frequency of each LSU (ROS) Video
Lock in an Open Loop from the Temperature detection result. (4 Colors/
Correction Resolution Ability: 1/4 Pixel unit)
53. 760-068
[NVM Name]: OLMAG-K-1
[PSW Display]: K-OLMAG
[Initial Value]: 100
[Setup Range]: 0~200
[Description]:
The normal Regi Control separately adjusts the Fast Scan direction image 100 %
magnification by switching the average frequency of each LSU (ROS) Video
Lock in an Open Loop from the Temperature detection result. (4 Colors/
Correction Resolution Ability: 1/4 Pixel unit)
54. 760-070
[NVM Name]: LD Light Quantity when Regi Control is performed [Y]
[PSW Display]: Y-LD light volume at last RegiCon
[Initial Value]: 0
[Setup Range]: 0~1023
[Description]: LD Light Quantity when Regi Control is performed.
55. 760-071
[NVM Name]: LD Light Quantity when Regi Control is performed [M]
[PSW Display]: M-LD light volume at last RegiCon
[Initial Value]: 0
[Setup Range]: 0~1023
[Description]: LD Light Quantity when Regi Control is performed.
56. 760-072
[NVM Name]: LD Light Quantity when Regi Control is performed [C]
[PSW Display]: C-LD light volume at last RegiCon
[Initial Value]: 0
[Setup Range]: 0~1023
[Description]: LD Light Quantity when Regi Control is performed.
57. 760-073
[NVM Name]: LD Light Quantity when Regi Control is performed [K]
[PSW Display]: K-LD light volume at last RegiCon
[Initial Value]: 0
[Setup Range]: 0~1023
[Description]: LD Light Quantity when Regi Control is performed.
58. 760-074
[NVM Name]: XSO-Y after LD Light Quantity Correction
[PSW Display]: Y-XSO after LD light volume change
[Initial Value]: 236
[Setup Range]: 0~472
[Description]: XSO value after correction based on the LD Light Quantity variation
59. 760-075
[NVM Name]: XSO-M after LD Light Quantity Correction
[PSW Display]: M-XSO after LD light volume change
[Initial Value]: 236
[Setup Range]: 0~472
[Description]: XSO value after correction based on the LD Light Quantity variation
60. 760-076
[NVM Name]: XSO-C after LD Light Quantity Correction
[PSW Display]: C-XSO after LD light volume change
[Initial Value]: 236
[Setup Range]: 0~472
[Description]: XSO value after correction based on the LD Light Quantity variation
61. 760-077
[NVM Name]: XSO-K after LD Light Quantity Correction
[PSW Display]: K-XSO after LD light volume change
[Initial Value]: 236
[Setup Range]: 0~472
[Description]: XSO value after correction based on the LD Light Quantity variation
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......