3. 4. 4. 9 DC132 Billing Data Matching & Serial No. Setup (System Data)
Function To match the Serial No., Product No., and Billing Count Value between the PSWs when
the MCU PWB or ESS PWB has been replaced, sets the Serial No., Product No. and Billing Count
Value of the old PSW to those of the new PSW.
DC132 is displayed only at occurrence of the following failures.
• 003-205 (when three items of billing counter mismatch)
• 103-207 (when even one Product No. is incorrect)
• 103-208 (when even one Serial No. is incorrect)
Reference
• This function is available only when a failure occurs.
(This function is supposed to be available with the failure active.)
• When the Service Mode is exited after the Serial No. has been set up, the failure will be
canceled.
(During failure, the test pattern print is not available.)
Procedure
1. Select the "System Data (NVM)" tab on the Service Mode screen.
2. Select [
DC132
] on the System Data screen.
3. The Billing Data Matching & Serial No. Setup screen is displayed.
[Case 1]
When all the PWB Serial No. have not been set, the PWB name is not displayed in
"List of PWBA not replaced" and the [M/C Serial No. Setup] button is enabled. Go to
Procedure 5.
[Case 2]
When any PWB Serial No. has been set, the PWB name is displayed in "List of PWBA
not replaced" and the [M/C Serial No. Setup] button is disabled. Go to Procedure 4.
4. Select one of the PWBs not replaced.
The [M/C Serial No. Setup] button becomes enabled.
5. Click the [M/C Serial No. Setup].
The M/C Serial No. Setup screen is displayed.
6. After entering the M/C Serial No. using the PSW keyboard, click [OK].
[Case 1]
The M/C Serial No. Confirmation screen is displayed.
[Case 2]
Check the match of the selected PWB Serial No. and the Serial No. entered. When the
result is OK, [M/C Serial No. Confirmation] screen is displayed.
7. After entering the M/C Serial No. again using the PSW keyboard, click [OK].
The M/C checks if the Serial No. entered matches the No. entered at the first time.
If the result is OK: The message "Execution Completed" is displayed.
If the result is NG: The re-enter screen is displayed.
Checking of M/C Information
1. Select the "System Data (NVM)" tab on the Service Mode screen.
2. Select [
DC132
] on the System Data screen.
3. Click [M/C Information] on the Billing Data Matching & Serial No. Setup screen.
4. Check the PWB to be replaced. Or, check the M/C Serial No. setting results.
• Serial No., Product No. and billing count are stored in three locations; 1 in the MCU
PWB and 2 in the ESS PWB.
• The IOT displayed indicates the one in the MCU PWB, and SYS1 and SYS2
indicate the ones in the ESS PWB.
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......