3-198
Chapter 3 Troubleshooting
3. 5. 4 DC135 HFSI List
1. 005-805
Document Feed
[PSW Display]: Document Feed
[Initial Value]: 0
[Setup Range]: 0~5,898,190
[Count Condition]: No. of DADF Feed after HFSI Counter Cleared.
[Description]:
2. 006-802
IIT Scan
[PSW Display]: IIT Scan
[Initial Value]: 0
[Setup Range]: 0~5,898,190
[Count Condition]: No. of Scan (Including pre-scan) after HFSI Counter Cleared.
[Description]:
3. 954-801
IBT Belt Unit Replacement Standard Value
[PSW Display]: IBT Belt Unit
[Initial Value]: 480 kPV
[Setup Range]: 0~99999999
[Count Condition]:
Copying when smaller than 8.5 x 11": +1
Copying when longer than 8.5 x 11": +2
[Description]:
Replacement of the IBT Belt Unit
Warning at 478.5 kPV
4. 954-802
2nd BTR Unit Replacement Standard Value
[PSW Display]: 2nd BTR Unit
[Initial Value]: 150 kPV
[Setup Range]: 0~99999999
[Count Condition]:
Copying when smaller than 8.5 x 11": +1
Copying when longer than 8.5 x 11": +2
[Description]:
Replacement of the 2nd BTR Unit
Warning at 98.5 kPV
5. 954-803
IBT Belt CLN Assy Replacement Standard Value
[PSW Display]: IBT Belt CLN Assy
[Initial Value]: 100 kPV
[Setup Range]: 0~99999999
[Count Condition]:
Copying when smaller than 8.5 x 11": +1
Copying when longer than 8.5 x 11": +2
[Description]:
Replacement of the IBT Belt CLN Assy
Warning at 98.5 kPV
6. 954-804
Fuser-CRU Standard Value
[PSW Display]: Fuser-CRU
[Initial Value]: 10000000
[Setup Range]: 0~99999999
[Count Condition]: Area conversion with A4L=100
[Description]:
Usage of Fuser CRU equivalent to A4L conversion
Warning at 900000
7. 954-806
1Tray Feed No. Standard Value
[PSW Display]: 1Tray Feed counter
[Initial Value]: 300000
[Setup Range]: 0~99999999
[Count Condition]: 1 sheet
[Description]: Replacement time of periodic replacement parts
8. 954-807
MSI Feed No. Standard Value
[PSW Display]: MSI Feed counter
[Initial Value]: 300000
[Setup Range]: 0~99999999
[Count Condition]: 1 sheet
[Description]: Replacement time of periodic replacement parts
9. 954-808
2Tray Feed No. Standard Value
[PSW Display]: 2Tray Feed counter
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......