3-258
Chapter 3 Troubleshooting
[Setup Range]: 0~1023
[Description]:
[Set ATC Control Nominal Value]+[ATC Environment Correction Value]+[ATC
Deterioration Correction Value]+[ATC Nominal Value OFFSET]
71. 752-158
[NVM Name]: ATC Control Nominal Value [C]
[PSW Display]: ATC Control Nominal Value [C]
[Initial Value]: 500
[Setup Range]: 0~1023
[Description]:
[Set ATC Control Nominal Value]+[ATC Environment Correction Value]+[ATC
Deterioration Correction Value]+[ATC Nominal Value OFFSET]
72. 752-159
[NVM Name]: ATC Control Nominal Value [K]
[PSW Display]: ATC Control Nominal Value [K]
[Initial Value]: 500
[Setup Range]: 0~1023
[Description]:
[Set ATC Control Nominal Value]+[ATC Environment Correction Value]+[ATC
Deterioration Correction Value]+[ATC Nominal Value OFFSET]
73. 752-162
[NVM Name]: Temperature Average Value
[PSW Display]: Temp Average
[Initial Value]: 100
[Setup Range]: 80~200
[Description]:
Temperature average value after converting the temperature sensor output to
temperature (80: -20 Degree Celsius, 100: 0 Degree Celsius, 200: 100 Degree
Celsius)
74. 752-163
[NVM Name]: Humidity Average Value
[PSW Display]: Humidity Average
[Initial Value]: 0
[Setup Range]: 0~100
[Description]: Humidity average value after converting the humidity sensor output to
humidity
75. 752-176
[NVM Name]: Failure Environment Sensor Temperature
[PSW Display]: Failure Environment SNR TEMP
[Initial Value]: 0
[Setup Range]: 0~1
[Description]: [Detection relation (Temperature/Humidity)] Temperature Sensor
Failure (Fixed as [Standard Temperature])
76. 752-177
[NVM Name]: Failure Environment Sensor Humidity
[PSW Display]: Failure Environment SNR Humidity
[Initial Value]: 0
[Setup Range]: 0~1
[Description]: [Detection relation (Temperature/Humidity)] Temperature Sensor
Failure (Fixed as [Standard Temperature])
77. 752-324
[NVM Name]: SW_DispMode
[PSW Display]: SW_DispMode
[Initial Value]: 0
[Setup Range]: 0~2
[Description]: Dis method changing SW (0=ATC+ICDC, 1=ICDC, 2=Timer Disp)
78. 752-357
[NVM Name]: Timer Dispense time [Y]
[PSW Display]: Timer Disp time [Y]
[Initial Value]: 5
[Setup Range]: 0~250
[Description]: Timer Disp Setup Time
79. 752-358
[NVM Name]: Timer Dispense time [M]
[PSW Display]: Timer Disp time [M]
[Initial Value]: 5
[Setup Range]: 0~250
[Description]: Timer Disp Setup Time
80. 752-359
[NVM Name]: Timer Dispense time [C]
[PSW Display]: Timer Disp time [C]
[Initial Value]: 5
[Setup Range]: 0~250
[Description]: Timer Disp Setup Time
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......