3-251
Chapter 3 Troubleshooting
[Setup Range]: 0~1023
[Description]: VH Output Value of #C Engine after Correction (All Speed common)
(1 Count=-1.173 V)
21. 751-203
[NVM Name]: [NVM Name]: VH Value after #K_BCR D Correction
[PSW Display]: #K_BCR DC corrected VH value 104 mm/s
[Initial Value]: 620
[Setup Range]: 0~1023
[Description]: VH Output Value of #K Engine after Correction (All Speed common)
(1 Count=-1.173 V)