97
●
Parameters (Slave 1 to 4)
The following are different from normal connection and
Master.
• RS485, DATA1 to 3 is fixed to Camera.
• DATA 4 is used for master-slave connection. Protocol is
fixed to Master-Slave and Baud Rate is fixed to 38400.
• When VCR is selected for 600 RECORDER in SETUP
MENU (refer to p. 71), the Protocol of SERIAL is fixed to
VCR. This parameter is activated when using a
Pananonic time-lapse VCR.
• When Protocol of SERIAL is displayed as “– – –“, Baud
Rate is set to the baud rate for firmware update.
Refer to p. 58 for details.
(Save Exit) button
Saves the configuration and closes the Data Port window.
(Cancel Exit) button
Cancels the configuration and closes the Data Port window.
■
Recorder
This window configures the recorder setting parameters:
whether the multiplexer board is installed in the unit, what is
the type of the recorder, what is the recorder unit address,
and whether the gen-lock is activated.
●
How to Display
To display this window, click on the
(Recorder Mode)
button in the main window (p. 80).
●
Parameters
• Recorder Control
Click on the desired radio button to determine the recorder
type.
OFF:
Select this when no recorder is connected to the
unit.
HD500:
Select this when a WJ-HD500 Series recorder
is connected to the unit.
HD100:
Select this when a WJ-HD100 Series recorder
is connected to the unit.
HD200:
Select this when a WJ-HD200 Series recorder
is connected to the unit.
VCR/VTR:
Select this when a time-lapse VCR is con-
nected to the unit.
Note:
VCR/VTR is selectable only in the Slave tabs.
The factory default setting is HD500.
• Unit Address
This parameter is configurable only when HD100, HD200 or
HD500 is selected in the Recorder window. When OFF is
selected there, this parameter is displayed in gray and not
configurable. 1 to 99 is selectable. The factory default set-
ting is 1.
Note:
If you connect a time-lapse VCR to the Master unit,
do the recorder setting in SETUP MENU. (Refer to
RECORDER in p. 71.) If you connect a time-lapse VCR
to Slave units, recorder setting is available in WJ-
SX150A Administrator Console.
MUX
MUX
Summary of Contents for WJ-SX 150A
Page 8: ...9 FEATURES OF THE MATRIX SWITCHER SYSTEM ...
Page 22: ...23 DETAILED PRODUCT DESCRIPTION ...
Page 29: ...31 INSTALLATIONS AND SYSTEM CONNECTIONS ...
Page 54: ...57 WJ SX150A SETUP PROCEDURES ...
Page 100: ...103 OPERATING PROCEDURES TERMINAL MODE ...
Page 119: ...123 OPERATING PROCEDURES PS DATA ...
Page 125: ...129 EXPANDED FUNCTION ...
Page 147: ...151 APPENDIX ...