152
[STX] [Response Command] : [E] [R] [n1] [n2] [n3] [ETX]
Parameters are omitted when the command format includes neither data nor status to send back.
(2) Reception Error
The unit sends back "NAK code 15H", followed by the parameters. The unit then resets the reception buffer and enters the
waiting mode for the next message. Parameter "e" identifies the error status.
[p] stands for parameter. Parameters are omitted when the command does not need to specify them.
2. Response Command
The unit returns messages to the PC with the following formats.
(1) Reception Command
When the reception was completed successfully, the unit sends back the "ACK code 06H" to the PC, and then the
response command.
COMMUNICATION PROTOCOL
The following pages detail the elements for communication between the unit and the PC.
When operating the PC, make sure to conform the serial port's communication speed to that of the unit.
The unit's communication speed is configurable by changing COM. SPEED in SETUP MENU. Data, parity and stop bits have
been set as follows:
Item
Parameter
Data length
8bit(fixed)
Parity bit
NONE(fixed)
Stop bit
1bit(fixed)
Hardware flow control (ER/DR/RS/CS)
Not supported yet
Software flow control (Xon/Xoff)
Not supported yet
Wait Time
Not supported yet
1. Transmission Command
The PC sends messages to the recorder in the following format. Also refer to the command table.
Code
(02H) ( ) – – – – – – – – – – – – – – – – – ( ) (03H)
[STX] [Transmission Command] : [p1] : [p2] : : [pn] [ETX]
ASCII
Code
(02H) ( ) – – – – – – – – – – – – – – – ( ) (03H)
[STX] [Response Command] : [p1] : [p2] : : [pn] [ETX]
ASCII
Code
[NAK] [e]
ASCII
(15H)
(3) Parameter Error
The unit returns "ACK code 06H", if the transmission code was not processed properly, followed by an error code.
Code
ASCII
1: Parity error (31H)
2: Overflow error (32H)
3: Framing error (33H)
4: Overrun error (34H)
5: Timeout error (35H)
[n] stands for an error code number. (Refer to p. 161.)
Note:
The unit returns [ACK] or [NAK] to the PC within 20 ms after the reception of [ETX] in a transmission.
(02H) ( )– – – – – – – – – – – – – (45H) (52H) 03H
Summary of Contents for WJ-SX 150A
Page 8: ...9 FEATURES OF THE MATRIX SWITCHER SYSTEM ...
Page 22: ...23 DETAILED PRODUCT DESCRIPTION ...
Page 29: ...31 INSTALLATIONS AND SYSTEM CONNECTIONS ...
Page 54: ...57 WJ SX150A SETUP PROCEDURES ...
Page 100: ...103 OPERATING PROCEDURES TERMINAL MODE ...
Page 119: ...123 OPERATING PROCEDURES PS DATA ...
Page 125: ...129 EXPANDED FUNCTION ...
Page 147: ...151 APPENDIX ...