78
• NORMAL
EXT.:
Select this to gen-lock the unit during the normal
operation.
002,004 to 255 (field):
Select one of these normal
recording rates if the asynchronous unit is connect-
ed to the unit.
The factory default setting is EXT.
• DYNAMIC REC
PRI.:
Select this to give recording priority to the camera
channel with the alarm input.
ONLY:
Select this to record the images from the alarm-
associated camera channel.
GROUP:
Select this to give recording priority to a group
of up to 4 camera channels associated to the alarm
input.
OFF:
Select this to deactivate the alarm priority mode.
The factory default setting is OFF.
• DUMMY BLACK
ON:
Select this to display the black picture for a camera
channel that is not connected to the camera.
OFF:
Select this to skip the camera channels that are
not connected to the camera in the sequence/spot
mode.
The factory default setting is ON.
• CAM SW LOSS
ON:
Select this to make “CAMSW LOSS R
∗
” light up on
the associated monitor when loss of the camera
switching pulse is detected.
OFF:
Select this not to make “CAMSW LOSS R
∗
”
appear on the associated monitor when loss of the
camera switching pulse is detected.
The factory default setting is ON.
Note:
If EXT. is selected for 910 ALARM/920 NORMAL,
the playback images cannot be displayed on the
monitors which are not connected to the EXT IN
connector. Confirm the images on those which are
connected to the recorder.
■
MUX CAMERA TITLE
●
How to Display
To display this menu on the monitor, move the cursor to
1000 MUX CAMERA TITLE in SETUP MENU by moving the
joystick to
D
or
C
. Then, press the CAM (SET) button. The
submenu appears on the monitor.
●
How to edit
The factory default settings are same as the illustration.
The editing procedure is the same as 500 CAMERA TITLE.
(Refer to p. 71.)
Notes:
• Up to 8 alphanumeric characters are available for
each Multiplexer board camera title.
• When moving the joystick to
D
at the last text box
of CAM 8 TITLE, the cursor will move to the first text
box of CAM 9 TITLE.
• When moving the joystick to
C
at the first text box
of CAM 9 TITLE, the cursor will move to the last text
box of CAM 8 TITLE.
• If five units are connected in the system, you can
configure no parameters for MASTER.
MUX
1000 MUX CAMERA TITLE
SWITCHER=SLAVE1(1 of 3)
CAM LCN TITLE CAM LCN TITLE
1 1 C01 9 09 C09
2 2 C02 10 10 C10
3 3 C03 11 11 C11
4 4 C04 12 12 C12
5 5 C05 13 13 C13
6 6 C06 14 14 C14
7 7 C07 15 15 C15
8 8 C08 16 16 C16
LCN:LOGICAL CAMERA NUMBER
Summary of Contents for WJ-SX 150A
Page 8: ...9 FEATURES OF THE MATRIX SWITCHER SYSTEM ...
Page 22: ...23 DETAILED PRODUCT DESCRIPTION ...
Page 29: ...31 INSTALLATIONS AND SYSTEM CONNECTIONS ...
Page 54: ...57 WJ SX150A SETUP PROCEDURES ...
Page 100: ...103 OPERATING PROCEDURES TERMINAL MODE ...
Page 119: ...123 OPERATING PROCEDURES PS DATA ...
Page 125: ...129 EXPANDED FUNCTION ...
Page 147: ...151 APPENDIX ...