56
Notification by e-mail
Alarm mail
The alarm mail contains an URL of an alarm image that saved on the recorder as follows.
Contents of the alarm mail
ND400 (192.168.0.250), alarm was occurred.
Alarm date:
xx-xxx-xxxx xx:xx:xx GMT xx:xx (Example: 01-JAN-2009
GMT+0:00)
Cause of alarm:
Displays an event type and a camera channel or an alarm
number (Example: COMMAND ALARM 5CH)
File name of alarm image:
The file name of the image attached to an e-mail.
URL:http://192.168.0.250/
Warning mail
The following mail will be sent to notify of a trouble occurrence to a registered address when the trouble occurs.
ND400 (192.168.0.250) STATUS REPORT.
DATE:
1-JAN-2009 12:00:00 GMT+0:00
STATUS: The description of the trouble will be displayed. (Ex. MAIN THERMAL ERROR)
Display
Description
DATE
Time and date when the trouble occurred will be displayed.
STATUS The description of the trouble will be displayed.
HDD capacity warning*
1
:
<Anything other than FULL>
NORMAL-HDD CAPACITY REMAINS **%
EVENT-HDD CAPACITY REMAINS **%
COPY-HDD CAPACITY REMAINS **%
** is remaining capacity (%).
<FULL>
EVENT-HDD FULL
COPY-HDD FULL
Power outage detection:
POWER LOSS
Recover from a power outage:
POWER RECOVERED
NW camera error detection:
CAM** COMMUNICATION ERROR
** is camera channel.
NW camera error recovery:
CAM** COMMUNICATION RECOVERED
** is camera channel.
NW camera error detection (audio):
CAM** COMMUNICATION ERROR (AUDIO)
** is camera channel.
NW camera error recovery (audio):
CAM** COMMUNICATION RECOVERED (AUDIO)
** is camera channel.
HDD smart warning*
2
:
Recorder: MAIN-y SMART WARNING
Extension unit: EXTx-y SMART WARNING
x is unit number, y is disk number.
HDD hour meter warning:
Recorder: MAIN-y HOUR METER WARNING
Extension unit: EXTx-y HOUR METER WARNING
x is unit number, y is disk number.