The gas detector fault icon will turn off after
approximately 1 minute, and the area around
the MENU button will flash in red.
●
If the gas detector is reconnected or the
removed gas detector is reinstalled, the alarm
stops, and the area around the MENU button,
GAS indicator, and door phone alarm display
indicator turn off.
●
After pressing the STOP ALARM button,
touching on the base unit will cause
the screen to return to the waiting state, and
the area around the MENU button will light up
in red. To display the gas detector fault icon,
touch on the Top Menu screen.
( Pages 20 to 21)
●
The GAS indicator appears only on the base unit.
●
The GAS indicator continues to appear, the area
around the MENU button continues to appear or
flash, and the alarm display indicator continues
to flash until the detector or detector wiring is
reconnected.
●
The gas detector fault icon can also be turned off
within 1 minute. ( Page 155)
●
The ventilation icon will turn off after
approximately 3 minutes, and the area around
the MENU button will flash in red.
●
Once the imperfect combustion state is no
longer detected, the alarm stops. Also, the
area around the MENU button, ALARM
indicator on the call sub-base unit alarm
indicator, and door phone alarm display
indicator turn off.
●
The area around the MENU button, ALARM
indicator, and alarm display indicator continue
to flash until the imperfect combustion state
(carbon monoxide) is no longer detected by the
gas/CO detector.
●
The ventilation icon can also be turned off
within 3 minutes. ( Page 155)
162
163
When the gas detector is disconnected or removed, the system reports a fault.
In the Event of Imperfect Combustion
In the Event of a Gas Detector Fault
Ventilation icon
flashes in red
When the imperfect combustion state (carbon monoxide) is detected by the gas/CO detector,
the system reports a fault.
Door phone
Alarm display indicator
Flashes in red
Alarm is sounding
How to stop the alarm sound
Procedures during alarms
This function is only available when using gas detectors with CO alarm functionality.
MENU button
Call sub-base unit
ALARM indicator
Flashes in red
Alarm is sounding
Door phone
Alarm display indicator
Flashes in red
Alarm is sounding
Gas detector fault
icon appears
in red
GAS
indicator
appears
in yellow
●
Press the STOP ALARM button.
(The alarm can also be turned off from
the building manager room.)
How to stop the alarm sound
Procedures during alarms
MENU button
Confirm button
Call sub-base unit
Alarm is sounding
In the Event of a Gas Leak or Disconnection
The alarm can be disabled.
Consult with the management
company or the company that
installed the system.
●
Press the STOP ALARM button. Note that the
gas/CO alarm will not turn off. (The alarm can
also be turned off from the building manager
room.)
●
Open the windows and doors to ventilate the
room.
●
Stop using the devices causing the incomplete
combustion state.
●
If the alarm does not stop, contact the store
where purchased or your nearest gas store.
●
If the gas detector is not experiencing a fault
such as the device being removed or a breaker
being tripped, contact your apartment manager
or system installer.
Note
Note
Note
INTRODUCTION
USUAL USAGE
SETTING ACCORDING TO
YOUR PREFERENCES
OPERATIONS AND MEASURES
WHEN ALARM GOES OFF
SECURITY ALARM SETTING
AND DISARMING
RECORD
MANAGEMENT
OTHER
Installer
Setting
復旧/警報音停止
RESET/ STOP ALARM
電源
POWER
ガス
GAS
復旧/警報音停止
RESET/ STOP ALARM
電源
POWER
●
For base unit
●
For base unit
STOP ALARM
button
STOP ALARM
button
and do not appear in the call
sub-base unit with monitor.
Note
(Beeps) The air is
contaminated. Open a window
and ventilate the room.
(Beeps)
does not appear in the call
sub-base unit with monitor.
Note