Chapter 6 Menu Operations — Menu list
Item
Description of settings
[BATT REMAIN FULL]
Sets the content of the battery remaining charge bar of SmartUI when a battery with charge level display
function is used.
[70%]:
Displays as full at 70%.
[100%]:
Displays as full at 100%.
f
Factory setting: [70%]
[BATTERY SETTING]
[BATTERY MODE]
Selects whether to set the near end voltage of a battery.
[AUTO]:
Automatically set.
[MANUAL]:
Manually set.
f
Factory setting: [AUTO]
[HYTRON140 NEAR
END]
Selects the near end voltage in steps of 0.1 V when [HYTRON140] is selected in the main menu
→
[BATTERY SETUP]
→
[BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]…[15.0V]
f
Factory setting: [13.1V]
[DIONIC HC NEAR END] Selects the near end voltage in steps of 0.1 V when [DIONIC HC] is selected in the main menu
→
[BATTERY SETUP]
→
[BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]…[15.0V]
f
Factory setting: [13.1V]
[ENDURA10 NEAR
END]
Selects the near end voltage in steps of 0.1 V when [ENDURA10] is selected in the main menu
→
[BATTERY SETUP]
→
[BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]…[15.0V]
f
Factory setting: [13.1V]
[PAG L96e NEAR END]
Selects the near end voltage in steps of 0.1 V when [PAG L96e] is selected in the main menu
→
[BATTERY SETUP]
→
[BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]…[15.0V]
f
Factory setting: [13.1V]
[TYPE A FULL]
Selects the voltage for full display in steps of 0.1 V when [TYPE A] is selected in the main menu
→
[BATTERY SETUP]
→
[BATTERY SELECT].
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[13.0V]…[17.0V]
f
Factory setting: [15.6V]
[TYPE A NEAR END]
Selects the near end voltage in steps of 0.1 V when [TYPE A] is selected in the main menu
→
[BATTERY
SETUP]
→
[BATTERY SELECT].
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[11.0V]…[15.0V]
f
Factory setting: [13.2V]
[TYPE A END]
Selects the end voltage in steps of 0.1 V when [TYPE A] is selected in the main menu
→
[BATTERY
SETUP]
→
[BATTERY SELECT].
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[11.0V]…[15.0V]
f
Factory setting: [12.5V]
[TYPE B FULL]
Selects the voltage for full display in steps of 0.1 V when [TYPE B] is selected in the main menu
→
[BATTERY SETUP]
→
[BATTERY SELECT].
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.
[13.0V]…[17.0V]
f
Factory setting: [15.9V]
[TYPE B NEAR END]
Selects the near end voltage in steps of 0.1 V when [TYPE B] is selected in the main menu
→
[BATTERY
SETUP]
→
[BATTERY SELECT].
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.
[11.0V]…[15.0V]
f
Factory setting: [12.9V]
[TYPE B END]
Selects the end voltage in steps of 0.1 V when [TYPE B] is selected in the main menu
→
[BATTERY
SETUP]
→
[BATTERY SELECT].
The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.
[11.0V]…[15.0V]
f
Factory setting: [12.5V]
[TYPE C FULL]
Selects the voltage for full display in steps of 0.1 V when [TYPE C] is selected in the main menu
→
[BATTERY SETUP]
→
[BATTERY SELECT].
[13.0V]…[17.0V]
f
Factory setting: [15.9V]
[TYPE C NEAR END]
Selects the near end voltage in steps of 0.1 V when [TYPE C] is selected in the main menu
→
[BATTERY
SETUP]
→
[BATTERY SELECT].
[11.0V]…[15.0V]
f
Factory setting: [13.2V]
[TYPE C END]
Selects the end voltage in steps of 0.1 V when [TYPE C] is selected in the main menu
→
[BATTERY
SETUP]
→
[BATTERY SELECT].
[11.0V]…[15.0V]
f
Factory setting: [12.5V]