151
Close
(platform closes)
Fault
Possible cause
Remedy
Platform does not close
Rotary switches, pushbut-
tons, or toggle switches de-
fective
Use test lamp to check con-
tacts in operating element ac-
cording to circuit diagram,
use ground connection JK at
PC board
PC board does not deliver
output on J 1/12, J43/90 or JK
Use test lamp to check PC
board according to circuit di-
agram
Motor contactor -K1 defective Check motor contactor
In its closed end position the
platform does not reach the
vehicle loading floor height
End of box insufficiently rein-
forced
Reinforce box according to
details in assembly drawing
Bearings worn out (after lon-
ger usage)
Replace bearing pins, bear-
ing bushes
Switch on Warnfix
(Warnfix is automatically switched on when the platform is opened or extended, left and
right lights are switched in parallel)
Fault
Possible cause
Remedy
Warning light does not flash
Short-circuit in lamp or ca-
bling
Repair short-circuit
Lamp defective
Replace
Summary of Contents for 200010121
Page 2: ...MBB C 1500 L THE EFFICIENT AND FUNCTIONALLY TAIL LIFT ...
Page 4: ...PALFINGER TAIL LIFTS ASSEMBLY INSTRUCTIONS TAIL LIFTS STANDARD ...
Page 5: ......
Page 7: ......
Page 66: ......
Page 68: ...PALFINGER TAIL LIFTS OPERATING INSTRUCTIONS TAIL LIFTS ...
Page 69: ......
Page 108: ...41 ...
Page 138: ...71 ...
Page 142: ...75 ...
Page 146: ...79 ...
Page 164: ...97 ...
Page 240: ...173 Retractable Tail Lift MBB R 1500 L FLAT 99 553 98 01 00 00 3 F LIFT CYL LIFT CYL ...
Page 243: ...176 Foldable Tail Lift 02 528 60 08 00 00 B M A R1 A DBV1 M S1 LIFT CYLINDER ...
Page 252: ...PALFINGER TAIL LIFTS OPERATING INSTRUCTIONS TAIL LIFTS ...
Page 253: ......
Page 292: ...41 ...
Page 322: ...71 ...
Page 326: ...75 ...
Page 330: ...79 ...
Page 348: ...97 ...
Page 424: ...173 Retractable Tail Lift MBB R 1500 L FLAT 99 553 98 01 00 00 3 F LIFT CYL LIFT CYL ...
Page 427: ...176 Foldable Tail Lift 02 528 60 08 00 00 B M A R1 A DBV1 M S1 LIFT CYLINDER ...