26 |
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
(01.2012) OM_BA_ORBIMAT_CA_01_EN
SETUP AND ASSEMBLY
ORBIMAT CA
| Operating instructions
Is the machine not starting the first time it is switched on?
X
Check whether the pilot light in the main switch is lit up.
Is the pilot light not lit up?
There is a problem with the power supply (no voltage, plug not inserted).
X
Check whether the power plug is properly inserted.
X
Have the power supply checked.
Is the pilot light lit up?
X
Check whether the STOP indicator (for active EMERGENCY-STOP) on the front panel is lit up.
Is the STOP indicator on the front panel lit up?
With external remote control connected: EMERGENCY-STOP switch is pressed.
1. Unlock EMERGENCY-STOP switch by turning it counterclockwise.
2. Switch off machine.
3. Wait at least 5 seconds and then switch machine on again.
Is an external remote control not connected?
The dummy plug is missing from the remote control connection, EMERGENCY-STOP is activated.
X
Insert dummy plug to close the EMERGENCY-STOP circuit if necessary.
Pumping out water
To protect the pump against possible dry running, the software stops pumping out after approx. 30 seconds.
Fig. 8: Main menu (long form)
1. In the main menu, call up the "System settings" menu item by turning the rotary knob.
2. Briefly press rotary knob.
The System settings sub-menu appears.
Summary of Contents for ORBIMAT 165 CA
Page 78: ...orbitalum tools gmbh Notizen Notes ...