7. Allow water pump to run until the water exits the drain hose under pressure.
8. Confirm "Cancel" by briefly pressing the rotary knob.
The water pump is switched off. The water pump is now filled with water and is ready for operation.
If the water does not exit the hose within a maximum of 10 seconds:
1. Cancel drainage, as prolonged dry running can damage the pump.
2. Check water level.
3. Check whether the pump is running and if a pumping sound can be heard.
Additional help see Sec. 9, Page 59 "Service and troubleshooting".