ORBIMAT CA
| Operating instructions
SETUP AND ASSEMBLY
•
The connections at Items 1–7 are intended for the connection of the various weld heads from the ORBIMATIC line.
The coding prevents plugs from being mixed up. The cooling water connections (water flow and return) are the
same.
1
5
6
7
4
2
3
1. Gas quantity setting
2. Connection of BUP
Control Box
3. ORB 1001 connection
4. Key switch
5. Remote control
connection
6. STOP indicator
(with EMERGENCY-
STOP active)
7. Multicard reader
Fig. 6: Front panel: Connections and control elements
•
Remote control connection
Connection for remote control (optional) or dummy plug.
If remote control is not being used and the dummy plug is not inserted, most of the system is deenergized. The
pilot light in the red main switch lights up, and the STOP indicator for active EMERGENCY-STOP lights up red.
•
Key switch
The key switch disables procedure modification.
A shortened selection menu (main menu) appears if procedure modification is disabled.
Key position (as shown): Modification enabled In the "disabled" key position, the key can be removed.
•
ORB 1001 connection
Connection of a residual oxygen meter (type ORB 1001) (optional).
For continuous monitoring of the forming gas: The portion of residual oxygen remains below a percental portion
which can be set at the device (e.g. 70 ppm).
•
Connection of BUP Control Box
For supplementary devices for control of the forming gas pressure (BUP: BackUp Pressure Control) (optional).
These supplementary devices record the gas pressure inside the pipe using a pressure sensor and change it using
a controllable gas valve.
•
Multicard reader
For the exchange of procedures between multiple machines, for the creation of backup copies of the system data
and for updating the system, languages, header data and the database for auto programming.
Memory cards which can be used: CF, SD, MMC, Smart Media and Sony Memory Stick
•
Gas quantity setting (weld gas)
Adjusting screw with sight glass for setting the weld gas quantity.
•
Other connection options (on device rear)
Optionally, the connection of an external keyboard (included in the scope of delivery) or an external printer and/or
monitor to the rear of the device is possible.
7.1.3
Operating concept
The main control elements are the rotary knob and five push switches. The current function assignment of these
switches is displayed in the fields at the bottom edge of the display. Direct access to standard functions (e.g. "start"
and "stop") is possible at all times.