52 |
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
(01.2012) OM_BA_ORBIMAT_CA_01_EN
OPERATION
ORBIMAT CA
| Operating instructions
Deleting data on the external memory card
1. In the main menu, select "System settings" > "Program settings"
2. Select "External memory" in the "Memory location" field.
3. Select deletion in the main menu via the "Delete procedure" button.
Red diskette symbol: Data is being deleted from the external card.
The system always saves logs on an external card.
The system-based required procedure "Default" and the folder "Default" cannot be deleted.
Copying data
1. Press the "Copy procedure" button in the main menu.
The following display appears:
Fig. 32: Copy functions
2. Press button for desired copy direction.
3. Press button for data to be copied (e.g. "A procedure from a folder").
4. Select and copy element (e.g. procedure).
8.10.2
Entering comments and application data ("Process details")
Useful information on individual parameters (material, gas type, electrode etc.) and comments (e.g. a description of the
seam preparation, an angle setting of the electrode with adapter) about a procedure can be entered for the operator.
This information may be required for ensuring consistent results while running the procedure.
Entering notes and comments
1. In the main menu, select "System settings" > "Program settings" > "Process details".
A list for entering process-relevant, "non-electrical" parameters appears in the display.
Fig. 33: Process details
2. Enter notes on the parameters in the corresponding fields and save them.