(01.2012) OM_BA_ORBIMAT_CA_01_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
| 17
ORBIMAT CA
| Operating instructions
TECHNICAL DATA
5. TECHNICAL DATA
5.1
System data
5.1.1
Components and parts
Welding system primarily comprised of
the following:
•
Welding power source
•
Operating buttons and rotary knob
•
Weld gas supply
•
Integrated water cooling system (only with 165 CA)
•
Function and drive control of the weld heads
•
Remote control connection option
•
Residual oxygen meter, forming gas control unit (BUP)
•
External keyboard, printer and monitor (VGA)
•
Function and drive control of the cold wire supply
Weld system type
Welding rectifier (inverter)
5.1.2
Technical Data
Parameter
Unit
OM 165 CA
OM 300 CA
Remarks
Input (mains)
Mains system
1 phase +PE
3 phase +PE
Mains input voltage
V (AV)
90 - 260
400
Permissible voltage tolerance
&
See mains v/- 15
OM165CA = Wide Range
Mains frequency
Hz
50-60
50-60
Continuous input current
A (AC)
14 (on 230V)
13
Continuous input
kVA
3,2 (on 230V)
9
Current consumption, max.
A (AC)
19 (on 230V)
20
Connection value, max.
kVA
4,4
13,5
Mains fuse
A
16
20
Slow-blow characteristic
Power factor (cos)
0,99 (with 100A)
0,7 (with 200A)
OM 165 CA : PFC
Output (welding circuit)
Setting range Weld current
A (DC)
2 - 165
5 -300
In 0.1 A increments
Weld current reproducibility
%
+/- 0,5
+/- 0,5
Rated current at 100 % ED
A (DC)
120
200
Rated current at 60 % ED
A (DC)
165
Rated current at 50 % ED
A (DC)
300
Min. weld voltage
V (DC)
10
10
Max. weld voltage
V (DC)
16
22
Max. open-circuit voltage
V (DC)
85
86
Min. cable diameter
mm
2
16
35
Max. ignition power
Joule
0,9
0,9
Max. ignition voltage
kV
8
8
Summary of Contents for ORBIMAT 165 CA
Page 78: ...orbitalum tools gmbh Notizen Notes ...
Page 79: ......