4-1
Section
Controller
50
Connecting to OMRON C200H PC
Controller
9-pin male
Connecting device
C200H-ASC02
Cables with connectors
9-pin male
Shielded wire
Connector Pin Arrangement
when Viewed from the Controller
6 Shield
Assembly and Connection of Communications Connector
An OMRON communications connector conforming to EMI standards is pro-
vided with the Controller. Use this communications connector or an equivalent
one.
Prepare a connection cable and a connector for the host computer. Refer to Ap-
pendix B Ordering Information for details.
Connection cable
Host computer side
XM2A-0901 Plug
(provided with
the Controller)
XM2S-0911
Hood (provided)
(see note 1)
Recommended cable
Hitachi Cable’s
CO-MA-VV-SB 5PX28AWG
(see note 2)
Controller side
Note
1. A connector conforming to EMI standards is provided with the Controller.
2. Use the above cable or an equivalent one with an external diameter of 7 mm.
Assembly of Connector
1, 2, 3...
1. Process the end of the cable as shown below.
Conductors
Braided shield
Shield tape
Cable bushing
•
Insert the cable into the cable bushing.
•
Untangle the braided shield for approximately 10 mm and fold it back on
the cable bushing.
•
Apply shield tape to the untangled braided shield.