7-1
Section
Trial Operation
118
7-1
Trial Operation
Check the following on the RD-ID System before the trial operation of the whole
system.
Items
Detail
Page
Power supply
and I/O lines
•
Are the power supply and I/O lines properly wired?
•
Are all the terminal screws tightened securely?
DIP switch
settings
•
Is the node number set correctly?
•
Are the communications specifications set correctly?
•
Is the communications distance mode set correctly?
•
Is the energy-saving mode set correctly?
Antenna
Is the Antenna connected properly?
Host
connection
Is the RS-232C or RS-485 connector connected
properly?
Location of
Antenna and
ID Tag
Are the Antenna and ID Tag located properly?
Procedure for Trial Operation
Turn power ON
Check that the supply voltage and the connection of power supply terminals are
correct.
Check that the RUN indicator of the Controller and the POWER indicator of the
Antenna are ON.
Offline test with the
Programming Console
Check that the communications between the Antenna and ID Tag are OK with or
without the host connected.
Online test with the host
Check the communications between the host and Controller with test commands.
Trial operation of the system
Check the operation of the whole system with actual commands executed.
Completion
By using the Programming Console, the communications between the Antenna
and ID Tag can be tested without the host connected. This test allows checking
of the mounting position of the Antenna and the movement speed of the ID Tag
before the trial operation of the whole system. Refer to Section 6 Programming
Console for details.
By using test commands, the communications between the Controller and host
can be tested. This test allows the checking of the cable connection and the pro-
cessing operation of communications before the trial operation of the whole sys-
tem.
•
Prepare a simple communications program on the host and transmit test com-
mands.
•
If the communications line is normal, the Controller returns the data received.
Check Items
Offline Test with
Programming Console
Communications Test
with Host