8-3
Section
Communications Time (Reference)
135
tions with the host. Use this for calculating the speed of the ID Tag for the
execution of auto commands.
Example
Command
Actual communications
time
Response
Note If auto commands are being used, the communications time will vary slightly de-
pending on when the ID Tag reaches the Antenna’s communication area. When
calculating the proper ID Tag speed, add one page to the actual number of pages
being processed (e.g., use 2 pages if only 1 page is being processed) and calcu-
late the speed from this number of pages and the width of the communication
area.
No Sync (Reference Values)
Writing
Reading
Number of bytes processed
Actual
communications
time (ms)
Writing
Reading
Number of bytes processed
Calculation Formula
Operation
Actual communications time
(msec)
Reading
T = 46.7N + 60.7
Writing
T = 52.8N + 113.5
Note N: Number of pages processed
Read-only Sync (Reference Values)
Reading
Number of bytes processed
Actual
communications
time (ms)
Number of bytes processed
Reading
Calculation Formula
Operation
Actual communications time
(msec)
Reading
T = 46.7N +107.4
Note N: Number of pages processed