2-1
Section
Controller
9
Refer to all sections following this section for the functions of the Controller in
detail. Refer to Section 4 Setting, Mounting and Connection Methods for the set-
tings and connections of the Controller.
No.
Name
Function
Description
1
Node number
switch
Used for node number
settings
The node number is used to identify each Controller when a single
host computer is connected to a maximum of 32 Controllers.
2
DIP switch
Used for mode
settings
Various settings are possible (e.g., communications
synchronization, energy-saving, communications distance,
termination resistance, baud rate, data length, parity, stop bit length,
communications mode, and time-out settings).
3
Indicator
The following indicators are available.
RUN
Green
RUN indicator
Turns ON when the Controller is in normal operation.
COMM
Green
Communications
indicator
Turns ON when the Controller is in communications with the ID Tag.
NORM
Green
Normal indicator
Turns ON and OFF once when the communications finish with no
error.
ERR
Red
Error indicator
Turned ON and OFF once if a communications error results. Turned
ON if a system error results.
4
Cover
Protection of SW1
through SW4 and the
Programming Console
port
Open the cover only when necessary.
5
Programming
Console port
Connecting to the
Programming Console
OMRON’s C200H-PRO27-E Programming Console (sold
separately) can be connected through the V700-P10 Programming
Console Conversion Cable (sold separately). The V700-P10 is
provided with a dedicated key sheet used for the operation of the
Programming Console.
6
Antenna Port
Connecting to the
Antenna
A single Antenna can be connected through the V700-A4
j
Antenna
Cable (sold separately).
The following Antennas are available.
•
V700-H01 (standard antenna, 250 x 200 mm in size)
•
V700-H02 (wide-field antenna, 650 x 200 mm in size)
7
RS-232C port
(V700-CD1D-V3)
Connecting to host
device
A personal computer or PC can be connected through the RS-232C
port.
RS-485 interface
(V700-CD2D-V3)
Connecting to host
device
A personal computer or PC can be connected through the RS-485
interface.
8
Power supply
terminals
Connecting to power supply
24 VDC+
Connecting to power
C24 VDC.
24 VDC–
supply
Connect 0 V.
GR
Connecting to ground
Ground this terminal at a resistance of less than 100
Ω
.
9
SYNC terminals
Used for synchronization
SYNC+
Connecting to
These terminals are used together for synchronizing more than one
SYNC–
synchronous signal
Controller in order to reduce the distance of mutual interference of
each corresponding Antenna.
10
RESET terminals
Connecting to RESET signal
RST
RESET signal
These terminals are used together in order to use external RESET
COM
COMMON signal
input.